1" Blind Flange PVC Schedule 80 (853-010)
The 853-010 is a 1" PVC Schedule 80 blind flange — a solid, unbored flange plate designed to cap or blank off the end of a flanged PVC pipeline, valve, or equipment nozzle. Unlike a standard flange, the blind flange has no center bore or pipe connection — the face is completely solid, creating a permanent or temporary pressure-rated termination at any mating 1" ANSI/ASME B16.5 Class 150 flanged connection when bolted down with a flat face gasket and standard bolt pattern.
Manufactured from rigid, dark gray PVC compound conforming to ASTM D1784 cell classification requirements, the Schedule 80 construction provides the mechanical strength and wall thickness required to withstand bolt-up clamping forces and full system pressure at the closed end of a flanged assembly. This makes the 853-010 the correct choice for capping flanged terminations in Schedule 80 chemical, industrial, and water treatment systems where the blind must match the pressure rating and chemical resistance of the surrounding pipeline.
The blind flange serves several critical functions in flanged piping systems. In new construction, it provides a pressure-rated temporary cap during hydrostatic pressure testing, allowing the system to be tested at full pressure before final tie-ins or equipment connections are made. In permanent installations, it closes off unused flanged nozzles on vessels, tanks, and manifolds — or terminates a flanged pipeline end that may be extended in a future phase. Unlike a threaded plug or solvent-weld cap, the bolted blind flange can be removed and reinstalled repeatedly without damaging the pipe or fitting, making it the preferred termination method wherever future access, inspection, or system extension is anticipated at a flanged connection point. The all-PVC construction provides excellent resistance to acids, caustics, chlorinated water, and a broad range of industrial process fluids, making the 853-010 a practical alternative to metal blind flanges in corrosive service environments.
Specifications:
| Attribute | Detail |
|---|---|
| Part Number | 853-010 |
| Material | PVC (Polyvinyl Chloride) |
| Schedule / Class | Schedule 80 |
| Fitting Type | Blind Flange |
| Center Bore | None (solid face) |
| Size | 1" |
| Flange Face | Flat Face (solid / unbored) |
| Flange Standard | ANSI/ASME B16.5 Class 150 Bolt Pattern |
| Connection Method | Bolted (flat face gasket required) |
| Pressure Rating | Rated per ASTM D2467 (temperature and size dependent) |
| Temperature Range | Up to 140°F (60°C) for pressure service |
| Color | Dark Gray |
| Standards | ASTM D2467, ASTM D1784 |
| Listing | NSF/ANSI 61 (potable water contact) |
Industries & Applications:
- Chemical Processing — Capping unused flanged nozzles on vessels, tanks, and chemical feed equipment in corrosive service environments where all-PVC construction eliminates metal corrosion and galvanic compatibility concerns
- Municipal Water & Wastewater — Pressure testing flanged pipeline assemblies at pump stations and treatment facilities, and permanently capping unused flanged ports on distribution and process equipment
- Industrial Process Piping — Temporary and permanent flanged terminations in high-pressure cooling water, process fluid, and recirculation systems requiring Schedule 80 pressure integrity at closed ends
- Water Treatment & Filtration — Blanking off unused nozzles on filter vessels, membrane housings, and chemical dosing equipment in potable water and industrial water treatment systems
- Irrigation & Agriculture — Capping flanged pipeline ends and unused manifold nozzles during system commissioning, pressure testing, and phased installation of large-scale pressurized irrigation systems
- HVAC & Mechanical — Terminating flanged pipe ends during construction phasing and pressure testing in chilled water and process cooling systems where PVC is specified for corrosion resistance
The 853-010 is a 1" PVC Schedule 80 blind flange — a solid, unbored flange plate designed to cap or blank off the end of a flanged PVC pipeline, valve, or equipment nozzle. Unlike a standard flange, the blind flange has no center bore or pipe connection — the face is completely solid, creating a permanent or temporary pressure-rated termination at any mating 1" ANSI/ASME B16.5 Class 150 flanged connection when bolted down with a flat face gasket and standard bolt pattern.
Manufactured from rigid, dark gray PVC compound conforming to ASTM D1784 cell classification requirements, the Schedule 80 construction provides the mechanical strength and wall thickness required to withstand bolt-up clamping forces and full system pressure at the closed end of a flanged assembly. This makes the 853-010 the correct choice for capping flanged terminations in Schedule 80 chemical, industrial, and water treatment systems where the blind must match the pressure rating and chemical resistance of the surrounding pipeline.
The blind flange serves several critical functions in flanged piping systems. In new construction, it provides a pressure-rated temporary cap during hydrostatic pressure testing, allowing the system to be tested at full pressure before final tie-ins or equipment connections are made. In permanent installations, it closes off unused flanged nozzles on vessels, tanks, and manifolds — or terminates a flanged pipeline end that may be extended in a future phase. Unlike a threaded plug or solvent-weld cap, the bolted blind flange can be removed and reinstalled repeatedly without damaging the pipe or fitting, making it the preferred termination method wherever future access, inspection, or system extension is anticipated at a flanged connection point. The all-PVC construction provides excellent resistance to acids, caustics, chlorinated water, and a broad range of industrial process fluids, making the 853-010 a practical alternative to metal blind flanges in corrosive service environments.
Specifications:
| Attribute | Detail |
|---|---|
| Part Number | 853-010 |
| Material | PVC (Polyvinyl Chloride) |
| Schedule / Class | Schedule 80 |
| Fitting Type | Blind Flange |
| Center Bore | None (solid face) |
| Size | 1" |
| Flange Face | Flat Face (solid / unbored) |
| Flange Standard | ANSI/ASME B16.5 Class 150 Bolt Pattern |
| Connection Method | Bolted (flat face gasket required) |
| Pressure Rating | Rated per ASTM D2467 (temperature and size dependent) |
| Temperature Range | Up to 140°F (60°C) for pressure service |
| Color | Dark Gray |
| Standards | ASTM D2467, ASTM D1784 |
| Listing | NSF/ANSI 61 (potable water contact) |
Industries & Applications:
- Chemical Processing — Capping unused flanged nozzles on vessels, tanks, and chemical feed equipment in corrosive service environments where all-PVC construction eliminates metal corrosion and galvanic compatibility concerns
- Municipal Water & Wastewater — Pressure testing flanged pipeline assemblies at pump stations and treatment facilities, and permanently capping unused flanged ports on distribution and process equipment
- Industrial Process Piping — Temporary and permanent flanged terminations in high-pressure cooling water, process fluid, and recirculation systems requiring Schedule 80 pressure integrity at closed ends
- Water Treatment & Filtration — Blanking off unused nozzles on filter vessels, membrane housings, and chemical dosing equipment in potable water and industrial water treatment systems
- Irrigation & Agriculture — Capping flanged pipeline ends and unused manifold nozzles during system commissioning, pressure testing, and phased installation of large-scale pressurized irrigation systems
- HVAC & Mechanical — Terminating flanged pipe ends during construction phasing and pressure testing in chilled water and process cooling systems where PVC is specified for corrosion resistance
- Part #:
- 853-010
- Product Family:
- Sch 80 PVC
- Carton Qty:
- 5
- Pallet Qty:
- 1440
- Size:
- 1"