2" Schedule 80 PVC Pipe Plain End - 1-5ft
The 2" Schedule 80 Gray PVC Pipe (Plain End, 5-Foot Length) is a heavy-duty, thick-wall thermoplastic pressure pipe manufactured to ASTM D1785, certified to NSF 61 and NSF 14, and rated at 400 PSI at 73°F — the correct Schedule 80 pipe for commercial and industrial irrigation mainlines, chemical distribution trunks, water treatment plant branch piping, pool and spa recirculation mains, and any application at this size where Schedule 40 wall thickness or pressure rating is insufficient for the system specification. The 2" size is one of the most important commercial mainline sizes in the Schedule 80 pipe line — appearing at the primary supply connection of commercial irrigation pump stations, the inlet and outlet headers of industrial filtration systems, the recirculation main of large commercial pools and aquatic centers, the trunk distribution piping of water treatment plants, and the process main connections of chemical processing facilities where flow demands have reached the upper range of the Schedule 80 true union ball valve series and pipe specification consistently calls for Schedule 80 construction throughout.
The Schedule 80 wall thickness is the fundamental specification advantage over Schedule 40 at every pipe size, and at 2" the performance gap is both concrete and commercially significant. Schedule 80 carries a 0.218" nominal wall versus the 0.154" wall of Schedule 40 at this size — a 42% increase in wall thickness that produces the 400 PSI cold working pressure rating versus Schedule 40's 280 PSI, a 43% higher pressure ceiling that delivers the engineering margin commercial irrigation designers, industrial piping engineers, and water treatment facility specifiers require when sizing mainline pipe at this service diameter. The thicker wall also provides greater resistance to mechanical impact during installation and in buried service, improved resistance to point loading and soil pressure in underground runs, and the structural integrity that commercial and industrial piping specifications demand at the 2" mainline size where system consequences of pipe failure are proportionally greater than at smaller branch sizes. Both schedules share the same 2.375" outside diameter at the 2" nominal size, meaning Schedule 80 pipe connects directly and interchangeably into Schedule 40 and Schedule 80 socket fittings — a practical advantage when working on mixed-schedule systems or upgrading an existing Schedule 40 mainline installation to Schedule 80 without disturbing socket fittings already cemented in place.
The gray color is the universal field identifier for Schedule 80 PVC pipe, and at the 2" commercial mainline size it carries particular weight. Systems at this diameter are inspected, permitted, and documented at a level of rigor that smaller residential branch sizes do not typically encounter — and the gray Schedule 80 identification provides immediate, unambiguous material class confirmation for inspectors, engineers, and facility maintenance teams without reference to installation records or pipe markings that may be obscured in buried or concealed runs. Gray means Schedule 80, and that visual confirmation persists through the full service life of the installation. For water treatment facilities, chemical processing plants, commercial irrigation systems, and regulated industrial environments where material traceability is both a specification requirement and an operational necessity, gray Schedule 80 pipe communicates its class at a glance from installation day forward.
Plain end pipe cuts cleanly to required length with a PVC pipe cutter, fine-tooth handsaw, or power saw and solvent cements directly into any standard IPS socket fitting without additional machining or end preparation. Deburr and bevel the cut end before applying solvent cement and inserting into the fitting socket for a full-strength, leak-free joint at consistent insertion depth. At the 2" size, use a heavy-body or medium-body solvent cement rated for the pipe schedule and fitting combination and follow the manufacturer's set and cure time recommendations before pressurizing the joint. The 5-foot length is the standard distribution and online-sale cut length — practical for equipment connections, maintenance repairs, short system runs, and project purchases where full 10-foot or 20-foot production sticks are impractical to ship or handle, particularly at the 2" diameter where pipe weight and handling requirements increase meaningfully over smaller sizes.
NSF 61 certification lists this pipe for potable water contact, and NSF 14 covers compliance with applicable plastics piping material standards — making it the correct pipe for municipal water treatment distribution, commercial well system mains, and institutional plumbing applications where NSF-listed materials are required at every system component.
Key Features:
- Schedule 80 gray PVC — 0.218" nominal wall, 400 PSI rated at 73°F
- Manufactured to ASTM D1785 — the governing standard for Schedule 80 PVC pressure pipe
- NSF 61 certified for potable water contact; NSF 14 listed
- Plain end for solvent cement installation into socket fittings
- 2.375" OD — dimensionally compatible with all 2" PVC Schedule 40 and Schedule 80 socket fittings
- 5-foot cut length for distribution, equipment connections, and repairs
- Gray color — universal Schedule 80 identification in the field
- Cell classification PVC 12454 per ASTM D1784
- Suitable for industrial, chemical, agricultural, and commercial mainline pressure piping
- Pressure derated above 73°F per standard PVC temperature-pressure curves
Specifications:
| Attribute | Value |
|---|---|
| Nominal Size | 2" |
| Schedule | Schedule 80 |
| Length | 5 Feet (Plain End) |
| Outside Diameter (OD) | 2.375" |
| Nominal Wall Thickness | 0.218" |
| Inside Diameter (ID) | 1.939" |
| Pressure Rating | 400 PSI @ 73°F (Non-Shock) |
| Material | PVC (Polyvinyl Chloride) Type 1, Grade 1 |
| Cell Classification | 12454 per ASTM D1784 |
| Color | Gray |
| End Type | Plain End (No Bell) |
| Connection Method | Solvent Cement (IPS Socket Fittings) |
| Manufacturing Standard | ASTM D1785 |
| Potable Water Certification | NSF/ANSI 61 |
| Plastics Standard Certification | NSF 14 |
| Max Service Temperature | 140°F (60°C) |
Industries & Applications:
- Irrigation & Agricultural Systems — The 2" size is the dominant pump discharge and primary distribution main size on commercial irrigation systems at farms, golf courses, sports field complexes, parks, and municipal landscape installations; Schedule 80's 400 PSI rating versus Schedule 40's 280 PSI provides the pressure margin that commercial irrigation engineers specify on pump station discharge headers, zone supply trunks, and primary distribution mains where operating pressures and pump shut-off head conditions demand more than Schedule 40 can safely provide
- Industrial Process Piping — Used on 2" process water mains, cooling water distribution headers, chemical transfer lines, compressed air distribution, and plant utility connections in manufacturing, chemical processing, pharmaceutical manufacturing support, and industrial facilities where Schedule 80 is the system-wide material standard and gray pipe identification confirms specification compliance at every point in the installed system
- Chemical Processing & Distribution — PVC's broad chemical resistance to acids, bases, chlorine, salts, oxidizing agents, and industrial solvents makes Schedule 80 the pipe of choice for 2" chemical distribution trunks, reagent supply mains, and process chemical transfer lines in water treatment plants and industrial processing environments; the 0.218" Schedule 80 wall provides the structural margin required under sustained chemical pressure service and the impact resistance important in active industrial processing environments
- Municipal Water & Wastewater Treatment — NSF 61 listed for potable water contact makes this pipe appropriate for 2" distribution branch mains, chemical feed header connections, filter vessel inlet and outlet piping, backwash supply and discharge connections, and instrumentation supply lines in water treatment plant environments where all materials in contact with treated water must carry NSF listing and Schedule 80 construction is the facility engineering standard for mainline pressure piping
- Pool & Spa — Commercial & Aquatic Facilities — The 2" size is one of the primary recirculation and equipment supply main sizes at large commercial pools, water parks, natatoriums, and aquatic centers; Schedule 80 PVC construction handles the continuous chlorine, salt, and pool treatment chemical exposure that corrodes metal pipe, and the 400 PSI rating and 0.218" wall satisfy the structural and engineering specifications that commercial aquatic facility designers apply to recirculation system main piping at this size
- Commercial Well Systems & Pump Stations — Used on 2" commercial well pump discharge mains, booster pump station supply and discharge headers, and high-flow point-of-entry treatment system connections on commercial, institutional, and light industrial properties where system flow rates and pressure demands have driven the design to the 2" mainline size; Schedule 80 construction and the 400 PSI pressure rating safely accommodate commercial pump shut-off head conditions and facility engineer specifications
- HVAC & Commercial Mechanical Systems — Specified on 2" chilled water mains, condenser water primary distribution headers, and primary hydronic heating and cooling supply and return connections in commercial and industrial mechanical systems where Schedule 80 PVC is the system material standard; at the 2" size these are primary mechanical room distribution mains rather than branch connections, and Schedule 80 construction satisfies the structural and pressure requirements that commercial mechanical engineers specify on primary system piping
- Aquaculture & Large-Scale Water Management — The 2" size handles the flow rates required for primary distribution, filtration system headers, and aeration supply mains at commercial aquaculture facilities, hatcheries, and large-scale recirculating aquaculture systems (RAS); Schedule 80 construction and broad chemical resistance to treatment compounds, oxygen, and disinfectants make this pipe a reliable primary distribution material for high-flow commercial aquaculture environments
The 2" Schedule 80 Gray PVC Pipe (Plain End, 5-Foot Length) is a heavy-duty, thick-wall thermoplastic pressure pipe manufactured to ASTM D1785, certified to NSF 61 and NSF 14, and rated at 400 PSI at 73°F — the correct Schedule 80 pipe for commercial and industrial irrigation mainlines, chemical distribution trunks, water treatment plant branch piping, pool and spa recirculation mains, and any application at this size where Schedule 40 wall thickness or pressure rating is insufficient for the system specification. The 2" size is one of the most important commercial mainline sizes in the Schedule 80 pipe line — appearing at the primary supply connection of commercial irrigation pump stations, the inlet and outlet headers of industrial filtration systems, the recirculation main of large commercial pools and aquatic centers, the trunk distribution piping of water treatment plants, and the process main connections of chemical processing facilities where flow demands have reached the upper range of the Schedule 80 true union ball valve series and pipe specification consistently calls for Schedule 80 construction throughout.
The Schedule 80 wall thickness is the fundamental specification advantage over Schedule 40 at every pipe size, and at 2" the performance gap is both concrete and commercially significant. Schedule 80 carries a 0.218" nominal wall versus the 0.154" wall of Schedule 40 at this size — a 42% increase in wall thickness that produces the 400 PSI cold working pressure rating versus Schedule 40's 280 PSI, a 43% higher pressure ceiling that delivers the engineering margin commercial irrigation designers, industrial piping engineers, and water treatment facility specifiers require when sizing mainline pipe at this service diameter. The thicker wall also provides greater resistance to mechanical impact during installation and in buried service, improved resistance to point loading and soil pressure in underground runs, and the structural integrity that commercial and industrial piping specifications demand at the 2" mainline size where system consequences of pipe failure are proportionally greater than at smaller branch sizes. Both schedules share the same 2.375" outside diameter at the 2" nominal size, meaning Schedule 80 pipe connects directly and interchangeably into Schedule 40 and Schedule 80 socket fittings — a practical advantage when working on mixed-schedule systems or upgrading an existing Schedule 40 mainline installation to Schedule 80 without disturbing socket fittings already cemented in place.
The gray color is the universal field identifier for Schedule 80 PVC pipe, and at the 2" commercial mainline size it carries particular weight. Systems at this diameter are inspected, permitted, and documented at a level of rigor that smaller residential branch sizes do not typically encounter — and the gray Schedule 80 identification provides immediate, unambiguous material class confirmation for inspectors, engineers, and facility maintenance teams without reference to installation records or pipe markings that may be obscured in buried or concealed runs. Gray means Schedule 80, and that visual confirmation persists through the full service life of the installation. For water treatment facilities, chemical processing plants, commercial irrigation systems, and regulated industrial environments where material traceability is both a specification requirement and an operational necessity, gray Schedule 80 pipe communicates its class at a glance from installation day forward.
Plain end pipe cuts cleanly to required length with a PVC pipe cutter, fine-tooth handsaw, or power saw and solvent cements directly into any standard IPS socket fitting without additional machining or end preparation. Deburr and bevel the cut end before applying solvent cement and inserting into the fitting socket for a full-strength, leak-free joint at consistent insertion depth. At the 2" size, use a heavy-body or medium-body solvent cement rated for the pipe schedule and fitting combination and follow the manufacturer's set and cure time recommendations before pressurizing the joint. The 5-foot length is the standard distribution and online-sale cut length — practical for equipment connections, maintenance repairs, short system runs, and project purchases where full 10-foot or 20-foot production sticks are impractical to ship or handle, particularly at the 2" diameter where pipe weight and handling requirements increase meaningfully over smaller sizes.
NSF 61 certification lists this pipe for potable water contact, and NSF 14 covers compliance with applicable plastics piping material standards — making it the correct pipe for municipal water treatment distribution, commercial well system mains, and institutional plumbing applications where NSF-listed materials are required at every system component.
Key Features:
- Schedule 80 gray PVC — 0.218" nominal wall, 400 PSI rated at 73°F
- Manufactured to ASTM D1785 — the governing standard for Schedule 80 PVC pressure pipe
- NSF 61 certified for potable water contact; NSF 14 listed
- Plain end for solvent cement installation into socket fittings
- 2.375" OD — dimensionally compatible with all 2" PVC Schedule 40 and Schedule 80 socket fittings
- 5-foot cut length for distribution, equipment connections, and repairs
- Gray color — universal Schedule 80 identification in the field
- Cell classification PVC 12454 per ASTM D1784
- Suitable for industrial, chemical, agricultural, and commercial mainline pressure piping
- Pressure derated above 73°F per standard PVC temperature-pressure curves
Specifications:
| Attribute | Value |
|---|---|
| Nominal Size | 2" |
| Schedule | Schedule 80 |
| Length | 5 Feet (Plain End) |
| Outside Diameter (OD) | 2.375" |
| Nominal Wall Thickness | 0.218" |
| Inside Diameter (ID) | 1.939" |
| Pressure Rating | 400 PSI @ 73°F (Non-Shock) |
| Material | PVC (Polyvinyl Chloride) Type 1, Grade 1 |
| Cell Classification | 12454 per ASTM D1784 |
| Color | Gray |
| End Type | Plain End (No Bell) |
| Connection Method | Solvent Cement (IPS Socket Fittings) |
| Manufacturing Standard | ASTM D1785 |
| Potable Water Certification | NSF/ANSI 61 |
| Plastics Standard Certification | NSF 14 |
| Max Service Temperature | 140°F (60°C) |
Industries & Applications:
- Irrigation & Agricultural Systems — The 2" size is the dominant pump discharge and primary distribution main size on commercial irrigation systems at farms, golf courses, sports field complexes, parks, and municipal landscape installations; Schedule 80's 400 PSI rating versus Schedule 40's 280 PSI provides the pressure margin that commercial irrigation engineers specify on pump station discharge headers, zone supply trunks, and primary distribution mains where operating pressures and pump shut-off head conditions demand more than Schedule 40 can safely provide
- Industrial Process Piping — Used on 2" process water mains, cooling water distribution headers, chemical transfer lines, compressed air distribution, and plant utility connections in manufacturing, chemical processing, pharmaceutical manufacturing support, and industrial facilities where Schedule 80 is the system-wide material standard and gray pipe identification confirms specification compliance at every point in the installed system
- Chemical Processing & Distribution — PVC's broad chemical resistance to acids, bases, chlorine, salts, oxidizing agents, and industrial solvents makes Schedule 80 the pipe of choice for 2" chemical distribution trunks, reagent supply mains, and process chemical transfer lines in water treatment plants and industrial processing environments; the 0.218" Schedule 80 wall provides the structural margin required under sustained chemical pressure service and the impact resistance important in active industrial processing environments
- Municipal Water & Wastewater Treatment — NSF 61 listed for potable water contact makes this pipe appropriate for 2" distribution branch mains, chemical feed header connections, filter vessel inlet and outlet piping, backwash supply and discharge connections, and instrumentation supply lines in water treatment plant environments where all materials in contact with treated water must carry NSF listing and Schedule 80 construction is the facility engineering standard for mainline pressure piping
- Pool & Spa — Commercial & Aquatic Facilities — The 2" size is one of the primary recirculation and equipment supply main sizes at large commercial pools, water parks, natatoriums, and aquatic centers; Schedule 80 PVC construction handles the continuous chlorine, salt, and pool treatment chemical exposure that corrodes metal pipe, and the 400 PSI rating and 0.218" wall satisfy the structural and engineering specifications that commercial aquatic facility designers apply to recirculation system main piping at this size
- Commercial Well Systems & Pump Stations — Used on 2" commercial well pump discharge mains, booster pump station supply and discharge headers, and high-flow point-of-entry treatment system connections on commercial, institutional, and light industrial properties where system flow rates and pressure demands have driven the design to the 2" mainline size; Schedule 80 construction and the 400 PSI pressure rating safely accommodate commercial pump shut-off head conditions and facility engineer specifications
- HVAC & Commercial Mechanical Systems — Specified on 2" chilled water mains, condenser water primary distribution headers, and primary hydronic heating and cooling supply and return connections in commercial and industrial mechanical systems where Schedule 80 PVC is the system material standard; at the 2" size these are primary mechanical room distribution mains rather than branch connections, and Schedule 80 construction satisfies the structural and pressure requirements that commercial mechanical engineers specify on primary system piping
- Aquaculture & Large-Scale Water Management — The 2" size handles the flow rates required for primary distribution, filtration system headers, and aeration supply mains at commercial aquaculture facilities, hatcheries, and large-scale recirculating aquaculture systems (RAS); Schedule 80 construction and broad chemical resistance to treatment compounds, oxygen, and disinfectants make this pipe a reliable primary distribution material for high-flow commercial aquaculture environments
Reviews
-
Very impressed with customer service!
I recently placed my first order with MAXX Supply and received the wrong item. I called their customer service to let them know and they told me I did not have to send back the wrong item and they would ship out the correct item that day to me! I was shocked because I have found most companies nowadays greatly lacking in customer service and doing the right thing for their customers. Needless to say, I will be doing more business again with MAXX Supply in the future!