8" Schedule 80 PVC Pipe Plain End - 1-5ft

Availability:
Ships same day if ordered by 2PM EST
$29.88 - $149.41
 

The 8" Schedule 80 Gray PVC Pipe (Plain End, 1-5 Foot Length) is a heavy-duty, thick-wall thermoplastic pressure pipe manufactured to ASTM D1785, certified to NSF 61 and NSF 14, and rated at 250 PSI at 73°F — the correct Schedule 80 pipe for the largest and highest-flow commercial and industrial PVC piping applications: primary irrigation system mains at maximum pump station scale, industrial process piping primary trunks carrying facility-level distribution volumes, chemical distribution headers in large processing environments, municipal water treatment plant primary branch and distribution piping, and large-volume aquatic facility recirculation mains where Schedule 80 wall thickness, structural integrity, impact resistance, and specification compliance are the governing requirements at this service diameter. The 8" size is the largest diameter in the Schedule 80 PVC pipe line available for online distribution — the point in the commercial pipe line where system flow volumes are at their absolute maximum for thermoplastic pressure pipe, where all engineering and specification decisions are made by licensed civil or mechanical engineers in formal construction documents reviewed and permitted by AHJs, and where the pipe specification itself carries the combined weight of structural engineering requirements, pressure performance requirements, regulatory compliance documentation, and long-term asset management standards that together define the correct material class for primary mainline piping at this scale.

The Schedule 80 wall thickness is the defining specification advantage over Schedule 40 at every pipe size, and at 8" it delivers both the thickest nominal wall in the standard commercial Schedule 80 pipe line and a pressure performance advantage over Schedule 40 that is among the widest in the large-diameter range. Schedule 80 carries a 0.500" nominal wall versus the 0.322" wall of Schedule 40 at the 8" size — a 55% increase in wall thickness that produces the 250 PSI cold working pressure rating versus Schedule 40's 160 PSI, a 56% higher pressure ceiling that is fully consistent with the wide Schedule 80 pressure advantage seen at the 6" size and that represents a substantial engineering margin over Schedule 40 at the 8" primary mainline diameter. A 0.500" wall at 8" is a structurally definitive specification — the half-inch wall thickness provides the maximum mechanical impact resistance in the standard commercial PVC line during the handling, rigging, and installation of the heaviest pipe in the series; the maximum resistance to soil loading, point contact pressure, bedding irregularities, and long-term ground movement in large-diameter buried primary mainline runs; and the structural rigidity under the combined effects of pipe weight, support span loading, internal pressure, and thermal movement that 8" primary main specifications require whether the pipe is buried, above-ground, or routed through large mechanical rooms, pump stations, and equipment vaults. Both schedules share the same 8.625" outside diameter at the 8" nominal size, meaning Schedule 80 pipe connects directly and interchangeably into Schedule 40 and Schedule 80 socket fittings — a practical and operationally significant advantage when working on large-diameter mixed-schedule systems or replacing Schedule 40 sections in an existing 8" primary main installation with Schedule 80 pipe without disturbing cemented fittings that are extremely costly and operationally disruptive to replace at this diameter.

The gray color is the universal field and facility identifier for Schedule 80 PVC pipe, and at the 8" primary mainline size it operates at the intersection of engineering specification, regulatory compliance, and long-term facility asset management in a way that no smaller pipe size in the commercial PVC line requires. Systems at this diameter are designed by licensed engineers, formally documented in construction drawings and specifications, submitted for permit review and AHJ approval, inspected during installation and at commissioning, and maintained and managed as capital infrastructure assets over service lives measured in decades. The gray Schedule 80 identification is the first and most permanent confirmation that the installed pipe meets the specification requirement at every point along the primary main — without reliance on pipe markings that may be obscured by soil, insulation, paint, or coating after installation; without dependence on installation records that may be archived, incomplete, or inaccessible years after construction; and without ambiguity for any inspector, maintenance engineer, facility manager, or capital planner who needs to confirm what is in the ground or overhead at a primary main location at any point in the system's service life. For municipal water treatment facilities, regulated industrial plants, large commercial irrigation systems, chemical processing environments, and aquatic venues where material traceability is simultaneously an engineering specification, a regulatory compliance obligation, and a capital asset management requirement, gray Schedule 80 pipe at 8" communicates its specification class definitively and permanently from the day of installation through the full operational life of the infrastructure.

Plain end pipe cuts to required length with a power saw or large-diameter PVC pipe cutter and solvent cements directly into any standard IPS socket fitting without additional machining or end preparation. At the 8" diameter, joint assembly is the most technically demanding in the standard commercial PVC pipe line, and correct technique is non-negotiable for joint integrity under system pressure. The large bonding surface area at 8" demands complete, even heavy-body solvent cement coverage across the full circumference of the pipe end and the entire depth of the fitting socket — partial coverage produces bond voids that compromise joint strength under pressure. Working time management is critical: the large bonded surface must be fully seated before initial cement set begins, which requires deliberate, pre-planned assembly with all components accessible and correctly positioned before cement application starts. Full cure time compliance before any system pressurization is mandatory — cure time requirements extend significantly at lower ambient temperatures and must be respected in full at 8" where the consequences of pressurizing a partially cured joint are proportionally greater than at any smaller pipe size. Use only a heavy-body solvent cement rated for Schedule 80 PVC at the 8" pipe diameter and the specific fitting combination being assembled. Follow the manufacturer's set time and full cure time recommendations for the ambient temperature at time of installation, and deburr and bevel the cut end thoroughly before cementing to ensure consistent insertion depth and a complete circumferential bond line. The 5-foot length is the standard distribution and online-sale cut length, practical for pump station connections, valve vault installations, equipment room supply and return connections, maintenance repairs, and project purchases where full 10-foot or 20-foot production sticks are impractical to handle or ship — at the 8" diameter, pipe weight, freight logistics, job site handling, rigging, and temporary support during installation are all at the maximum for the commercial Schedule 80 pipe line, and the 5-foot distribution format serves the repair, equipment connection, and short-run application needs that drive online purchasing at this largest standard commercial diameter.

NSF 61 certification lists this pipe for potable water contact, and NSF 14 covers compliance with applicable plastics piping material standards — making it the correct pipe for municipal water treatment primary distribution, large municipal and commercial well system mains, and large institutional plumbing applications where NSF-listed materials are required at every component of the primary distribution system at maximum flow volume and service scale.

Key Features:

  • Schedule 80 gray PVC — 0.500" nominal wall, 250 PSI rated at 73°F
  • 56% higher pressure rating than 8" Schedule 40 (250 PSI vs. 160 PSI)
  • Thickest nominal wall in the standard commercial Schedule 80 pipe line
  • Manufactured to ASTM D1785 — the governing standard for Schedule 80 PVC pressure pipe
  • NSF 61 certified for potable water contact; NSF 14 listed
  • Plain end for solvent cement installation into socket fittings
  • 8.625" OD — dimensionally compatible with all 8" PVC Schedule 40 and Schedule 80 socket fittings
  • 5-foot cut length for distribution, equipment connections, and repairs
  • Gray color — universal Schedule 80 identification in the field
  • Cell classification PVC 12454 per ASTM D1784
  • Suitable for the largest-diameter industrial, chemical, agricultural, municipal, and commercial mainline pressure piping applications
  • Pressure derated above 73°F per standard PVC temperature-pressure curves

Specifications:

Attribute Value
Nominal Size 8"
Schedule Schedule 80
Length 5 Feet (Plain End)
Outside Diameter (OD) 8.625"
Nominal Wall Thickness 0.500"
Inside Diameter (ID) 7.625"
Pressure Rating 250 PSI @ 73°F (Non-Shock)
Material PVC (Polyvinyl Chloride) Type 1, Grade 1
Cell Classification 12454 per ASTM D1784
Color Gray
End Type Plain End (No Bell)
Connection Method Solvent Cement (IPS Socket Fittings)
Manufacturing Standard ASTM D1785
Potable Water Certification NSF/ANSI 61
Plastics Standard Certification NSF 14
Max Service Temperature 140°F (60°C)

Industries & Applications:

  • Irrigation & Agricultural Systems — The 8" size is the largest primary pump station discharge main and the highest-volume principal distribution trunk in commercial PVC irrigation systems, used at the largest golf course irrigation plants, large-acreage commercial and corporate agricultural operations, regional park district and sports complex irrigation systems, and large municipal landscape and greenway installations where system flow volume has exceeded the capacity of 6" primary mains; Schedule 80's 250 PSI rating versus Schedule 40's 160 PSI delivers a 56% pressure advantage that gives commercial irrigation engineers the full safety margin they require on primary discharge mains at the highest pump station flow and pressure conditions in the system — where surge, water hammer, and shut-off head conditions are at their most severe in the commercial PVC irrigation pipe range
  • Industrial Process Piping — Used on 8" primary process water trunks, cooling tower primary supply and return mains, large-volume chemical transfer headers, and the highest-flow plant utility connections in large manufacturing, heavy chemical processing, pharmaceutical manufacturing, refinery support, and large industrial facilities where Schedule 80 is the system-wide material standard, gray identification confirms specification compliance at every point in the primary distribution system, and the 0.500" wall delivers the structural rigidity, impact resistance, and mechanical robustness required at the primary trunk level in the largest and most demanding active industrial environments
  • Chemical Processing & Distribution — PVC's broad resistance to acids, bases, chlorine, oxidizing agents, industrial salts, and process chemicals makes Schedule 80 the correct pipe material for 8" chemical distribution trunks, bulk chemical transfer mains, and primary reagent supply headers at the largest water treatment plants, industrial chemical processing facilities, and chemical manufacturing environments; the 0.500" Schedule 80 wall — the thickest in the commercial pipe line — provides the structural margin, impact resistance, and mechanical robustness required under sustained chemical pressure service at this maximum commercial mainline size where system scale, chemical service severity, and the operational consequences of component failure all collectively demand the highest available specification in the commercial PVC pipe class
  • Municipal Water & Wastewater Treatment — NSF 61 listed for potable water contact makes this pipe appropriate for 8" primary distribution mains, chemical feed header connections, filter vessel primary inlet and outlet piping, backwash supply and discharge headers, primary sludge and process water transfer connections, and the highest-flow process connections in water treatment plant and water reclamation facility environments where all materials in contact with treated water must carry NSF listing, Schedule 80 construction is the facility engineering standard for primary pressure piping at the largest service sizes, and material traceability is a documentation, regulatory compliance, and long-term asset management requirement across the full service life of the primary infrastructure
  • Pool & Spa — Largest Commercial & Aquatic Facilities — The 8" size is used on the highest-flow primary pump suction and discharge mains, main recirculation headers, and primary equipment room supply and return connections at the largest commercial natatoriums, major water parks, large wave pools, surf parks, and regional and national-level aquatic centers where system flow volume at the primary recirculation loop has driven pipe sizing to the 8" large-diameter range; Schedule 80 PVC construction handles the continuous chlorine, salt, acid wash, and pool treatment chemical exposure that rapidly degrades metal pipe alternatives, and the 250 PSI rating and 0.500" wall satisfy the structural and engineering specifications that aquatic facility engineers apply to primary recirculation and equipment connection piping at maximum commercial aquatic facility scale
  • Municipal & Large Commercial Well Systems and Booster Stations — Used on 8" high-capacity municipal and large commercial well pump discharge mains, regional booster pump station primary supply and discharge headers, and large-diameter point-of-entry treatment system trunk connections on municipal water systems, large commercial campuses, and institutional properties where system flow demands have driven the well or booster station design to the 8" primary mainline size; Schedule 80 construction and the 250 PSI rating accommodate the shut-off head and surge pressure conditions of the largest municipal and commercial pump installations with the structural margin that 8" primary main engineering specifications require
  • HVAC & Largest Commercial and Industrial Mechanical Systems — Specified on 8" primary chilled water mains, condenser water primary distribution headers, and the highest-capacity primary hydronic heating and cooling supply and return connections in large commercial campus, industrial, and institutional mechanical systems where Schedule 80 PVC is the system material standard; at the 8" size these are the central plant primary distribution connections at maximum scale — the mains feeding entire campus distribution loops, large industrial facility sections, or multi-building institutional complexes — where pipe schedule, pressure rating, wall thickness, structural performance, and specification documentation carry their full engineering weight in the licensed mechanical engineer's system design and material specification
  • Aquaculture & Large-Scale Recirculating Systems — The 8" size handles the highest flow rates in commercial aquaculture PVC piping, used on primary distribution headers, large mechanical and biological filtration system primary connections, high-volume aeration and oxygenation supply mains, and primary water conditioning and exchange connections at the largest commercial aquaculture facilities, regional and national-scale fish hatcheries, and large recirculating aquaculture systems (RAS) where system production scale has driven primary piping to the 8" large-diameter range; Schedule 80 construction, the 0.500" wall, broad chemical resistance, and NSF 61 listing make this pipe the correct primary distribution material at the highest level of commercial aquaculture production and water management infrastructure
(No reviews yet)
Width:
8.63 (in)
Height:
60.00 (in)
Depth:
8.63 (in)
Current Stock:
Adding to cart… The item has been added
 

The 8" Schedule 80 Gray PVC Pipe (Plain End, 1-5 Foot Length) is a heavy-duty, thick-wall thermoplastic pressure pipe manufactured to ASTM D1785, certified to NSF 61 and NSF 14, and rated at 250 PSI at 73°F — the correct Schedule 80 pipe for the largest and highest-flow commercial and industrial PVC piping applications: primary irrigation system mains at maximum pump station scale, industrial process piping primary trunks carrying facility-level distribution volumes, chemical distribution headers in large processing environments, municipal water treatment plant primary branch and distribution piping, and large-volume aquatic facility recirculation mains where Schedule 80 wall thickness, structural integrity, impact resistance, and specification compliance are the governing requirements at this service diameter. The 8" size is the largest diameter in the Schedule 80 PVC pipe line available for online distribution — the point in the commercial pipe line where system flow volumes are at their absolute maximum for thermoplastic pressure pipe, where all engineering and specification decisions are made by licensed civil or mechanical engineers in formal construction documents reviewed and permitted by AHJs, and where the pipe specification itself carries the combined weight of structural engineering requirements, pressure performance requirements, regulatory compliance documentation, and long-term asset management standards that together define the correct material class for primary mainline piping at this scale.

The Schedule 80 wall thickness is the defining specification advantage over Schedule 40 at every pipe size, and at 8" it delivers both the thickest nominal wall in the standard commercial Schedule 80 pipe line and a pressure performance advantage over Schedule 40 that is among the widest in the large-diameter range. Schedule 80 carries a 0.500" nominal wall versus the 0.322" wall of Schedule 40 at the 8" size — a 55% increase in wall thickness that produces the 250 PSI cold working pressure rating versus Schedule 40's 160 PSI, a 56% higher pressure ceiling that is fully consistent with the wide Schedule 80 pressure advantage seen at the 6" size and that represents a substantial engineering margin over Schedule 40 at the 8" primary mainline diameter. A 0.500" wall at 8" is a structurally definitive specification — the half-inch wall thickness provides the maximum mechanical impact resistance in the standard commercial PVC line during the handling, rigging, and installation of the heaviest pipe in the series; the maximum resistance to soil loading, point contact pressure, bedding irregularities, and long-term ground movement in large-diameter buried primary mainline runs; and the structural rigidity under the combined effects of pipe weight, support span loading, internal pressure, and thermal movement that 8" primary main specifications require whether the pipe is buried, above-ground, or routed through large mechanical rooms, pump stations, and equipment vaults. Both schedules share the same 8.625" outside diameter at the 8" nominal size, meaning Schedule 80 pipe connects directly and interchangeably into Schedule 40 and Schedule 80 socket fittings — a practical and operationally significant advantage when working on large-diameter mixed-schedule systems or replacing Schedule 40 sections in an existing 8" primary main installation with Schedule 80 pipe without disturbing cemented fittings that are extremely costly and operationally disruptive to replace at this diameter.

The gray color is the universal field and facility identifier for Schedule 80 PVC pipe, and at the 8" primary mainline size it operates at the intersection of engineering specification, regulatory compliance, and long-term facility asset management in a way that no smaller pipe size in the commercial PVC line requires. Systems at this diameter are designed by licensed engineers, formally documented in construction drawings and specifications, submitted for permit review and AHJ approval, inspected during installation and at commissioning, and maintained and managed as capital infrastructure assets over service lives measured in decades. The gray Schedule 80 identification is the first and most permanent confirmation that the installed pipe meets the specification requirement at every point along the primary main — without reliance on pipe markings that may be obscured by soil, insulation, paint, or coating after installation; without dependence on installation records that may be archived, incomplete, or inaccessible years after construction; and without ambiguity for any inspector, maintenance engineer, facility manager, or capital planner who needs to confirm what is in the ground or overhead at a primary main location at any point in the system's service life. For municipal water treatment facilities, regulated industrial plants, large commercial irrigation systems, chemical processing environments, and aquatic venues where material traceability is simultaneously an engineering specification, a regulatory compliance obligation, and a capital asset management requirement, gray Schedule 80 pipe at 8" communicates its specification class definitively and permanently from the day of installation through the full operational life of the infrastructure.

Plain end pipe cuts to required length with a power saw or large-diameter PVC pipe cutter and solvent cements directly into any standard IPS socket fitting without additional machining or end preparation. At the 8" diameter, joint assembly is the most technically demanding in the standard commercial PVC pipe line, and correct technique is non-negotiable for joint integrity under system pressure. The large bonding surface area at 8" demands complete, even heavy-body solvent cement coverage across the full circumference of the pipe end and the entire depth of the fitting socket — partial coverage produces bond voids that compromise joint strength under pressure. Working time management is critical: the large bonded surface must be fully seated before initial cement set begins, which requires deliberate, pre-planned assembly with all components accessible and correctly positioned before cement application starts. Full cure time compliance before any system pressurization is mandatory — cure time requirements extend significantly at lower ambient temperatures and must be respected in full at 8" where the consequences of pressurizing a partially cured joint are proportionally greater than at any smaller pipe size. Use only a heavy-body solvent cement rated for Schedule 80 PVC at the 8" pipe diameter and the specific fitting combination being assembled. Follow the manufacturer's set time and full cure time recommendations for the ambient temperature at time of installation, and deburr and bevel the cut end thoroughly before cementing to ensure consistent insertion depth and a complete circumferential bond line. The 5-foot length is the standard distribution and online-sale cut length, practical for pump station connections, valve vault installations, equipment room supply and return connections, maintenance repairs, and project purchases where full 10-foot or 20-foot production sticks are impractical to handle or ship — at the 8" diameter, pipe weight, freight logistics, job site handling, rigging, and temporary support during installation are all at the maximum for the commercial Schedule 80 pipe line, and the 5-foot distribution format serves the repair, equipment connection, and short-run application needs that drive online purchasing at this largest standard commercial diameter.

NSF 61 certification lists this pipe for potable water contact, and NSF 14 covers compliance with applicable plastics piping material standards — making it the correct pipe for municipal water treatment primary distribution, large municipal and commercial well system mains, and large institutional plumbing applications where NSF-listed materials are required at every component of the primary distribution system at maximum flow volume and service scale.

Key Features:

  • Schedule 80 gray PVC — 0.500" nominal wall, 250 PSI rated at 73°F
  • 56% higher pressure rating than 8" Schedule 40 (250 PSI vs. 160 PSI)
  • Thickest nominal wall in the standard commercial Schedule 80 pipe line
  • Manufactured to ASTM D1785 — the governing standard for Schedule 80 PVC pressure pipe
  • NSF 61 certified for potable water contact; NSF 14 listed
  • Plain end for solvent cement installation into socket fittings
  • 8.625" OD — dimensionally compatible with all 8" PVC Schedule 40 and Schedule 80 socket fittings
  • 5-foot cut length for distribution, equipment connections, and repairs
  • Gray color — universal Schedule 80 identification in the field
  • Cell classification PVC 12454 per ASTM D1784
  • Suitable for the largest-diameter industrial, chemical, agricultural, municipal, and commercial mainline pressure piping applications
  • Pressure derated above 73°F per standard PVC temperature-pressure curves

Specifications:

Attribute Value
Nominal Size 8"
Schedule Schedule 80
Length 5 Feet (Plain End)
Outside Diameter (OD) 8.625"
Nominal Wall Thickness 0.500"
Inside Diameter (ID) 7.625"
Pressure Rating 250 PSI @ 73°F (Non-Shock)
Material PVC (Polyvinyl Chloride) Type 1, Grade 1
Cell Classification 12454 per ASTM D1784
Color Gray
End Type Plain End (No Bell)
Connection Method Solvent Cement (IPS Socket Fittings)
Manufacturing Standard ASTM D1785
Potable Water Certification NSF/ANSI 61
Plastics Standard Certification NSF 14
Max Service Temperature 140°F (60°C)

Industries & Applications:

  • Irrigation & Agricultural Systems — The 8" size is the largest primary pump station discharge main and the highest-volume principal distribution trunk in commercial PVC irrigation systems, used at the largest golf course irrigation plants, large-acreage commercial and corporate agricultural operations, regional park district and sports complex irrigation systems, and large municipal landscape and greenway installations where system flow volume has exceeded the capacity of 6" primary mains; Schedule 80's 250 PSI rating versus Schedule 40's 160 PSI delivers a 56% pressure advantage that gives commercial irrigation engineers the full safety margin they require on primary discharge mains at the highest pump station flow and pressure conditions in the system — where surge, water hammer, and shut-off head conditions are at their most severe in the commercial PVC irrigation pipe range
  • Industrial Process Piping — Used on 8" primary process water trunks, cooling tower primary supply and return mains, large-volume chemical transfer headers, and the highest-flow plant utility connections in large manufacturing, heavy chemical processing, pharmaceutical manufacturing, refinery support, and large industrial facilities where Schedule 80 is the system-wide material standard, gray identification confirms specification compliance at every point in the primary distribution system, and the 0.500" wall delivers the structural rigidity, impact resistance, and mechanical robustness required at the primary trunk level in the largest and most demanding active industrial environments
  • Chemical Processing & Distribution — PVC's broad resistance to acids, bases, chlorine, oxidizing agents, industrial salts, and process chemicals makes Schedule 80 the correct pipe material for 8" chemical distribution trunks, bulk chemical transfer mains, and primary reagent supply headers at the largest water treatment plants, industrial chemical processing facilities, and chemical manufacturing environments; the 0.500" Schedule 80 wall — the thickest in the commercial pipe line — provides the structural margin, impact resistance, and mechanical robustness required under sustained chemical pressure service at this maximum commercial mainline size where system scale, chemical service severity, and the operational consequences of component failure all collectively demand the highest available specification in the commercial PVC pipe class
  • Municipal Water & Wastewater Treatment — NSF 61 listed for potable water contact makes this pipe appropriate for 8" primary distribution mains, chemical feed header connections, filter vessel primary inlet and outlet piping, backwash supply and discharge headers, primary sludge and process water transfer connections, and the highest-flow process connections in water treatment plant and water reclamation facility environments where all materials in contact with treated water must carry NSF listing, Schedule 80 construction is the facility engineering standard for primary pressure piping at the largest service sizes, and material traceability is a documentation, regulatory compliance, and long-term asset management requirement across the full service life of the primary infrastructure
  • Pool & Spa — Largest Commercial & Aquatic Facilities — The 8" size is used on the highest-flow primary pump suction and discharge mains, main recirculation headers, and primary equipment room supply and return connections at the largest commercial natatoriums, major water parks, large wave pools, surf parks, and regional and national-level aquatic centers where system flow volume at the primary recirculation loop has driven pipe sizing to the 8" large-diameter range; Schedule 80 PVC construction handles the continuous chlorine, salt, acid wash, and pool treatment chemical exposure that rapidly degrades metal pipe alternatives, and the 250 PSI rating and 0.500" wall satisfy the structural and engineering specifications that aquatic facility engineers apply to primary recirculation and equipment connection piping at maximum commercial aquatic facility scale
  • Municipal & Large Commercial Well Systems and Booster Stations — Used on 8" high-capacity municipal and large commercial well pump discharge mains, regional booster pump station primary supply and discharge headers, and large-diameter point-of-entry treatment system trunk connections on municipal water systems, large commercial campuses, and institutional properties where system flow demands have driven the well or booster station design to the 8" primary mainline size; Schedule 80 construction and the 250 PSI rating accommodate the shut-off head and surge pressure conditions of the largest municipal and commercial pump installations with the structural margin that 8" primary main engineering specifications require
  • HVAC & Largest Commercial and Industrial Mechanical Systems — Specified on 8" primary chilled water mains, condenser water primary distribution headers, and the highest-capacity primary hydronic heating and cooling supply and return connections in large commercial campus, industrial, and institutional mechanical systems where Schedule 80 PVC is the system material standard; at the 8" size these are the central plant primary distribution connections at maximum scale — the mains feeding entire campus distribution loops, large industrial facility sections, or multi-building institutional complexes — where pipe schedule, pressure rating, wall thickness, structural performance, and specification documentation carry their full engineering weight in the licensed mechanical engineer's system design and material specification
  • Aquaculture & Large-Scale Recirculating Systems — The 8" size handles the highest flow rates in commercial aquaculture PVC piping, used on primary distribution headers, large mechanical and biological filtration system primary connections, high-volume aeration and oxygenation supply mains, and primary water conditioning and exchange connections at the largest commercial aquaculture facilities, regional and national-scale fish hatcheries, and large recirculating aquaculture systems (RAS) where system production scale has driven primary piping to the 8" large-diameter range; Schedule 80 construction, the 0.500" wall, broad chemical resistance, and NSF 61 listing make this pipe the correct primary distribution material at the highest level of commercial aquaculture production and water management infrastructure
Size:
8"