Cap, Slip PVC Schedule 40 3" (447-030)
This 3" Schedule 40 PVC Slip Cap provides a permanent, solvent-cement closure for any standard 3" PVC pipe end in commercial and light industrial piping systems. Constructed in white Schedule 40 PVC, it offers the corrosion resistance and chemical compatibility required across a wide range of fluid handling applications where a pipe end must be sealed definitively, flush, and without the need for threaded fittings or additional transition hardware.
The slip socket interior is sized to accept a 3" PVC pipe end for a permanent solvent-cement bond, enclosing the pipe terminus in a clean, dome-shaped cap profile that withstands system pressure from within. Unlike a spigot plug, which closes an unused port on an existing fitting hub, the slip cap terminates the pipe run itself — making it the correct choice when a 3" pipe end is being permanently closed at the end of a main, a dead-leg branch, or a stubbed-out future connection point. At 3", this cap is most commonly encountered closing out large-diameter irrigation mains, distribution headers, fire suppression branch ends, and process water supply lines during phased construction or system expansion where a pipe run is installed ahead of its final termination point.
Rated to 260 psi at 73°F, this cap is suited for standard commercial and light industrial water distribution and irrigation service within its pressure class. Its PVC composition provides excellent resistance to corrosion, scale buildup, chlorinated water, and a broad range of chemical exposures, making it a reliable long-term closure in moisture-prone or chemically active environments where metal caps would corrode or add unnecessary weight to the assembly. NSF/ANSI 61 listing confirms suitability for potable water contact.
Apply solvent cement to both the pipe end exterior and the fitting socket interior per ASTM D2564 procedures, using a primer appropriate for the pipe and fitting schedule. Insert the pipe fully into the socket and maintain a quarter-turn during assembly for even cement distribution across the joint surface. Ensure full pipe insertion before the cement begins to set — at 3", partial insertion can result in an incomplete joint with reduced pressure integrity. Allow adequate cure time before pressurizing the system, and derate pressure ratings for elevated temperatures per published derating curves.
Specifications:
| Attribute | Detail |
|---|---|
| Part Number | 447-030 |
| Fitting Type | Cap |
| Connection Type | Slip (Socket End) |
| Size | 3" |
| Schedule / Series | Schedule 40 |
| Material | PVC (Polyvinyl Chloride) |
| Color | White |
| Pressure Rating | 260 psi @ 73°F (verify against manufacturer pressure tables) |
| ASTM Standard | D2466 |
| NSF/ANSI | NSF/ANSI 61 Listed |
| Joint Method | Solvent Cement (ASTM D2564) |
| Temperature Range | Up to 140°F (derate pressure for elevated temps) |
| End Configuration | Single Slip Socket — terminal / closure fitting |
| Bond Type | Permanent (not removable after cure) |
Industries & Applications:
- Irrigation & Water Distribution — Permanently closes 3" PVC mainline pipe ends at zone terminations, stubbed-out future connection points, and dead-leg branches in agricultural and municipal irrigation systems during phased construction or seasonal system modifications
- Commercial Plumbing — Caps 3" PVC supply main ends, riser stubs, and branch terminations in commercial building water distribution systems during construction phasing, pressure testing, or permanent end-of-line closures
- Industrial Process Piping — Seals 3" pipe ends on process water distribution headers, cooling water mains, and chemical supply lines in water treatment, manufacturing, and chemical processing facilities where a permanent, flush pipe-end closure is required
- Fire Suppression Systems — Closes 3" branch ends and dead-leg stubs in Schedule 40 PVC fire suppression distribution systems during installation phasing or system testing where a pressure-rated permanent cap is required
- Water Treatment & Aquaculture — Used to permanently close 3" pipe ends on recirculating system mains, filter feed headers, and tank distribution assemblies where NSF/ANSI 61 compliance and long-term chemical resistance are required at terminal pipe locations
- HVAC & Mechanical Systems — Caps 3" PVC pipe ends on cooling tower supply mains, chilled water distribution headers, and chemically treated water systems during construction, system expansion, or permanent end-of-line closures within the Schedule 40 pressure rating class
This 3" Schedule 40 PVC Slip Cap provides a permanent, solvent-cement closure for any standard 3" PVC pipe end in commercial and light industrial piping systems. Constructed in white Schedule 40 PVC, it offers the corrosion resistance and chemical compatibility required across a wide range of fluid handling applications where a pipe end must be sealed definitively, flush, and without the need for threaded fittings or additional transition hardware.
The slip socket interior is sized to accept a 3" PVC pipe end for a permanent solvent-cement bond, enclosing the pipe terminus in a clean, dome-shaped cap profile that withstands system pressure from within. Unlike a spigot plug, which closes an unused port on an existing fitting hub, the slip cap terminates the pipe run itself — making it the correct choice when a 3" pipe end is being permanently closed at the end of a main, a dead-leg branch, or a stubbed-out future connection point. At 3", this cap is most commonly encountered closing out large-diameter irrigation mains, distribution headers, fire suppression branch ends, and process water supply lines during phased construction or system expansion where a pipe run is installed ahead of its final termination point.
Rated to 260 psi at 73°F, this cap is suited for standard commercial and light industrial water distribution and irrigation service within its pressure class. Its PVC composition provides excellent resistance to corrosion, scale buildup, chlorinated water, and a broad range of chemical exposures, making it a reliable long-term closure in moisture-prone or chemically active environments where metal caps would corrode or add unnecessary weight to the assembly. NSF/ANSI 61 listing confirms suitability for potable water contact.
Apply solvent cement to both the pipe end exterior and the fitting socket interior per ASTM D2564 procedures, using a primer appropriate for the pipe and fitting schedule. Insert the pipe fully into the socket and maintain a quarter-turn during assembly for even cement distribution across the joint surface. Ensure full pipe insertion before the cement begins to set — at 3", partial insertion can result in an incomplete joint with reduced pressure integrity. Allow adequate cure time before pressurizing the system, and derate pressure ratings for elevated temperatures per published derating curves.
Specifications:
| Attribute | Detail |
|---|---|
| Part Number | 447-030 |
| Fitting Type | Cap |
| Connection Type | Slip (Socket End) |
| Size | 3" |
| Schedule / Series | Schedule 40 |
| Material | PVC (Polyvinyl Chloride) |
| Color | White |
| Pressure Rating | 260 psi @ 73°F (verify against manufacturer pressure tables) |
| ASTM Standard | D2466 |
| NSF/ANSI | NSF/ANSI 61 Listed |
| Joint Method | Solvent Cement (ASTM D2564) |
| Temperature Range | Up to 140°F (derate pressure for elevated temps) |
| End Configuration | Single Slip Socket — terminal / closure fitting |
| Bond Type | Permanent (not removable after cure) |
Industries & Applications:
- Irrigation & Water Distribution — Permanently closes 3" PVC mainline pipe ends at zone terminations, stubbed-out future connection points, and dead-leg branches in agricultural and municipal irrigation systems during phased construction or seasonal system modifications
- Commercial Plumbing — Caps 3" PVC supply main ends, riser stubs, and branch terminations in commercial building water distribution systems during construction phasing, pressure testing, or permanent end-of-line closures
- Industrial Process Piping — Seals 3" pipe ends on process water distribution headers, cooling water mains, and chemical supply lines in water treatment, manufacturing, and chemical processing facilities where a permanent, flush pipe-end closure is required
- Fire Suppression Systems — Closes 3" branch ends and dead-leg stubs in Schedule 40 PVC fire suppression distribution systems during installation phasing or system testing where a pressure-rated permanent cap is required
- Water Treatment & Aquaculture — Used to permanently close 3" pipe ends on recirculating system mains, filter feed headers, and tank distribution assemblies where NSF/ANSI 61 compliance and long-term chemical resistance are required at terminal pipe locations
- HVAC & Mechanical Systems — Caps 3" PVC pipe ends on cooling tower supply mains, chilled water distribution headers, and chemically treated water systems during construction, system expansion, or permanent end-of-line closures within the Schedule 40 pressure rating class
- Part #:
- 447-030
- Product Family:
- Sch 40 PVC
- Size: