Coupling, FPT x FPT PVC Schedule 40 1" (430-010)

SKU:
430-010
|
UPC:
25528724030
Availability:
Typically ships within 24 hrs
$0.92

This 1" Schedule 40 PVC Threaded Coupling (FPT x FPT) provides a straight-through inline connection for two 1" male NPT-threaded pipe ends, nipples, or fitting outlets in all-threaded PVC piping systems — the standard fitting for joining two threaded components inline without introducing solvent-cement joints or directional changes into the assembly. Constructed in white Schedule 40 PVC, it offers the corrosion resistance and chemical compatibility required across a wide range of commercial plumbing, irrigation, and light industrial fluid handling applications where threaded construction is specified or preferred throughout the system.

Both the inlet and outlet are cut to 1" FPT (Female Pipe Thread) geometry per NPT tapered thread standards, each accepting any standard 1" male NPT pipe end, nipple, or fitting for a pressure-tight mechanical connection when made up with thread sealant or PTFE tape. As the fundamental straight-through connector in all-threaded PVC assemblies, the FPT coupling joins two male-threaded components in a continuous inline run — at pipe-to-pipe extension joints where a longer threaded run requires two nipple sections, at repair sections where a damaged nipple or pipe length must be replaced inline, at valve station assemblies where a male-threaded transition fitting must connect to a downstream male-threaded pipe section, and at distribution manifold assembly points where two male-threaded components must be joined without a direction change at the connection. The FPT x FPT coupling requires male pipe ends or nipples on both sides — it should not be confused with the riser extender (434 series, MPT x FPT), which has a male-threaded inlet that threads directly into a female port without requiring a nipple on one side, or with the slip coupling (429 series), which connects socket pipe ends with solvent-cement bonds rather than threaded connections. At 1", this is the highest-demand entry in the 430 series — appearing throughout all-threaded PVC irrigation valve station assemblies, zone header distribution runs, commercial plumbing branch supply connections, pump station threaded pipe runs, and chemical feed distribution assemblies where 1" is the dominant all-threaded PVC system diameter and straight-through threaded inline connections are required at multiple assembly points throughout the system.

Rated to approximately 450 psi at 73°F, this coupling is suited for standard commercial and light industrial water distribution and irrigation service within its pressure class. Its PVC composition provides excellent resistance to corrosion, scale, chlorinated water, and a broad range of chemical exposures, making it a reliable long-term alternative to metal couplings in moisture-prone or chemically active environments. NSF/ANSI 61 listing confirms suitability for potable water contact, including use in drinking water distribution and treatment systems.

Install using a quality pipe thread sealant or PTFE tape on both male NPT pipe ends before engagement. Avoid over-torquing — PVC threads require hand-tight plus one to two turns; excessive force can crack the fitting or distort thread engagement at the coupling body. Derate pressure ratings for elevated temperatures per published derating curves.


Specifications:

Attribute Detail
Part Number 430-010
Fitting Type Coupling
Connection Type FPT x FPT (Female Pipe Thread × Female Pipe Thread)
Size 1"
Schedule / Series Schedule 40
Material PVC (Polyvinyl Chloride)
Color White
Pressure Rating 450 psi @ 73°F (verify against manufacturer pressure tables)
ASTM Standard D2464
NSF/ANSI NSF/ANSI 61 Listed
Thread Standard NPT (National Pipe Taper)
Temperature Range Up to 140°F (derate pressure for elevated temps)
End Configuration FPT x FPT — both ends accept 1" male NPT pipe ends or nipples

Industries & Applications:

  • Irrigation & Water Distribution — Joins two 1" male-threaded nipple sections, pipe-to-fitting transition stubs, and valve station threaded run segments inline in residential, light commercial, and agricultural irrigation all-threaded PVC assemblies where a straight-through threaded connection at the dominant 1" all-threaded valve station diameter is required at pipe extension joints, repair sections, and distribution manifold inline connection points throughout the system
  • Commercial Plumbing — Provides inline straight-through threaded connections between 1" male-threaded pipe ends, nipple stubs, and fitting outlet threads in commercial building water distribution systems where all-threaded PVC construction is specified and a straight-through connection at the common 1" branch supply diameter is needed without direction change or size reduction at the joint
  • Pump Station Assemblies — Connects two 1" male-threaded sections of pump station discharge headers, suction line threaded runs, bypass line connections, and valve cluster threaded pipe segments in pump station installations where all-threaded Schedule 40 PVC construction is maintained and straight-through inline connections are required at multiple points along the 1" threaded distribution assembly
  • Industrial Process Piping — Joins two 1" male-threaded sections of process water distribution runs, chemical feed lines, instrument supply manifolds, and equipment feed connections in water treatment, chemical processing, and manufacturing facilities where all-threaded Schedule 40 PVC construction requires straight-through inline connections at 1" threaded assembly extension and repair points
  • Chemical Handling — Provides a corrosion-resistant straight-through inline connection between 1" male-threaded sections of chemical feed distribution lines, dosing manifold runs, and injection system threaded assemblies conveying acids, caustics, fertilizer solutions, and other fluids incompatible with metal couplings where threaded PVC construction is maintained throughout the distribution assembly
  • Water Treatment & Aquaculture — Used at inline straight-through connection points on 1" all-threaded process water distribution runs, chemical dosing manifold threaded sections, and treatment equipment threaded pipe assemblies where NSF/ANSI 61 compliance and chemical resistance are required at every male-to-female threaded connection throughout the system
(No reviews yet)
Width:
1.69 (in)
Height:
2.06 (in)
Depth:
1.69 (in)
Condition:
New
Current Stock:
Adding to cart… The item has been added

This 1" Schedule 40 PVC Threaded Coupling (FPT x FPT) provides a straight-through inline connection for two 1" male NPT-threaded pipe ends, nipples, or fitting outlets in all-threaded PVC piping systems — the standard fitting for joining two threaded components inline without introducing solvent-cement joints or directional changes into the assembly. Constructed in white Schedule 40 PVC, it offers the corrosion resistance and chemical compatibility required across a wide range of commercial plumbing, irrigation, and light industrial fluid handling applications where threaded construction is specified or preferred throughout the system.

Both the inlet and outlet are cut to 1" FPT (Female Pipe Thread) geometry per NPT tapered thread standards, each accepting any standard 1" male NPT pipe end, nipple, or fitting for a pressure-tight mechanical connection when made up with thread sealant or PTFE tape. As the fundamental straight-through connector in all-threaded PVC assemblies, the FPT coupling joins two male-threaded components in a continuous inline run — at pipe-to-pipe extension joints where a longer threaded run requires two nipple sections, at repair sections where a damaged nipple or pipe length must be replaced inline, at valve station assemblies where a male-threaded transition fitting must connect to a downstream male-threaded pipe section, and at distribution manifold assembly points where two male-threaded components must be joined without a direction change at the connection. The FPT x FPT coupling requires male pipe ends or nipples on both sides — it should not be confused with the riser extender (434 series, MPT x FPT), which has a male-threaded inlet that threads directly into a female port without requiring a nipple on one side, or with the slip coupling (429 series), which connects socket pipe ends with solvent-cement bonds rather than threaded connections. At 1", this is the highest-demand entry in the 430 series — appearing throughout all-threaded PVC irrigation valve station assemblies, zone header distribution runs, commercial plumbing branch supply connections, pump station threaded pipe runs, and chemical feed distribution assemblies where 1" is the dominant all-threaded PVC system diameter and straight-through threaded inline connections are required at multiple assembly points throughout the system.

Rated to approximately 450 psi at 73°F, this coupling is suited for standard commercial and light industrial water distribution and irrigation service within its pressure class. Its PVC composition provides excellent resistance to corrosion, scale, chlorinated water, and a broad range of chemical exposures, making it a reliable long-term alternative to metal couplings in moisture-prone or chemically active environments. NSF/ANSI 61 listing confirms suitability for potable water contact, including use in drinking water distribution and treatment systems.

Install using a quality pipe thread sealant or PTFE tape on both male NPT pipe ends before engagement. Avoid over-torquing — PVC threads require hand-tight plus one to two turns; excessive force can crack the fitting or distort thread engagement at the coupling body. Derate pressure ratings for elevated temperatures per published derating curves.


Specifications:

Attribute Detail
Part Number 430-010
Fitting Type Coupling
Connection Type FPT x FPT (Female Pipe Thread × Female Pipe Thread)
Size 1"
Schedule / Series Schedule 40
Material PVC (Polyvinyl Chloride)
Color White
Pressure Rating 450 psi @ 73°F (verify against manufacturer pressure tables)
ASTM Standard D2464
NSF/ANSI NSF/ANSI 61 Listed
Thread Standard NPT (National Pipe Taper)
Temperature Range Up to 140°F (derate pressure for elevated temps)
End Configuration FPT x FPT — both ends accept 1" male NPT pipe ends or nipples

Industries & Applications:

  • Irrigation & Water Distribution — Joins two 1" male-threaded nipple sections, pipe-to-fitting transition stubs, and valve station threaded run segments inline in residential, light commercial, and agricultural irrigation all-threaded PVC assemblies where a straight-through threaded connection at the dominant 1" all-threaded valve station diameter is required at pipe extension joints, repair sections, and distribution manifold inline connection points throughout the system
  • Commercial Plumbing — Provides inline straight-through threaded connections between 1" male-threaded pipe ends, nipple stubs, and fitting outlet threads in commercial building water distribution systems where all-threaded PVC construction is specified and a straight-through connection at the common 1" branch supply diameter is needed without direction change or size reduction at the joint
  • Pump Station Assemblies — Connects two 1" male-threaded sections of pump station discharge headers, suction line threaded runs, bypass line connections, and valve cluster threaded pipe segments in pump station installations where all-threaded Schedule 40 PVC construction is maintained and straight-through inline connections are required at multiple points along the 1" threaded distribution assembly
  • Industrial Process Piping — Joins two 1" male-threaded sections of process water distribution runs, chemical feed lines, instrument supply manifolds, and equipment feed connections in water treatment, chemical processing, and manufacturing facilities where all-threaded Schedule 40 PVC construction requires straight-through inline connections at 1" threaded assembly extension and repair points
  • Chemical Handling — Provides a corrosion-resistant straight-through inline connection between 1" male-threaded sections of chemical feed distribution lines, dosing manifold runs, and injection system threaded assemblies conveying acids, caustics, fertilizer solutions, and other fluids incompatible with metal couplings where threaded PVC construction is maintained throughout the distribution assembly
  • Water Treatment & Aquaculture — Used at inline straight-through connection points on 1" all-threaded process water distribution runs, chemical dosing manifold threaded sections, and treatment equipment threaded pipe assemblies where NSF/ANSI 61 compliance and chemical resistance are required at every male-to-female threaded connection throughout the system
Part #:
430-010
Product Family:
Sch 40 PVC
Size:
1"