Female Adapter, Slip x FPT PVC Schedule 40 6" (435-060)

SKU:
435-060
|
UPC:
25528711467
Availability:
Typically ships within 24 hrs
$24.24
 
 

The 435-060 is a 6" Schedule 40 PVC Female Adapter with a Slip x FPT configuration. This fitting transitions a cemented PVC pipe run to a threaded connection at the same nominal size — the slip socket accepts 6" PVC pipe for solvent cementing on the pipe side, while the Female Pipe Thread (FPT) outlet on the opposite end receives any male-threaded (MPT) fitting, valve, pump flange adapter, or equipment port of the same nominal size. No size reduction occurs; the female adapter is a same-size connection-type transition fitting, converting a permanent cemented pipe end into a serviceable threaded port at full bore.

The female adapter occupies a distinct and essential role in PVC pressure piping systems. Where a coupling joins two cemented pipe ends and a union provides a disassemblable break point within a cemented run, the female adapter is the boundary fitting — it terminates the cemented pipe system at a defined point and presents a threaded female port for connection to whatever threaded component, valve, or equipment lies downstream. Once the adapter is cemented to the pipe, the FPT outlet functions exactly as a threaded port would in any other context: it can receive and release male-threaded connections repeatedly without disturbing the cemented pipe assembly upstream.

At 6", the 435-060 is a large-format adapter sized for high-volume commercial and industrial piping applications. The 6" female adapter is most commonly encountered at the interface between large-diameter PVC distribution mains and the threaded inlets and outlets of major equipment — large pump housings, large ball valves or butterfly valves with threaded end connections, large filter vessels, flow meters, and storage tank ports — where the supply or distribution infrastructure is 6" cemented PVC and the equipment connection is male-threaded at the same nominal size. It also appears at flanged assemblies where a threaded nipple bridges the female adapter to a companion flange fitting, and at system endpoints where the 6" cemented main must terminate at a threaded isolation valve or equipment inlet.

The same-size configuration — 6" slip to 6" FPT — means no flow restriction occurs at the adapter. The full bore of the 6" pipe passes through the fitting unobstructed, and the FPT outlet presents the same nominal bore to the downstream connection. This distinguishes the female adapter from a reducing bushing (which changes size) and from a union (which provides disassembly within the pipe run) — the female adapter's sole function is the connection-type transition from cemented to threaded at the same pipe size.

At 6" diameter, the cemented slip socket requires careful solvent welding practice — thorough, even primer and cement coverage across the full socket interior and pipe end surface is essential given the significantly larger joint surface area at this size. A two-person assembly is recommended: one to apply cement and seat the pipe, one to hold alignment firmly through the full set period. Pipe must be inserted to full socket depth and held without rotation until the joint sets. Thread sealant tape (PTFE) or pipe dope rated for PVC service should be applied to all male threads assembled into the FPT outlet before installation, and downstream pipe or equipment weight should be supported independently rather than cantilevered from the adapter body.

Manufactured in white Schedule 40 PVC, the 435-060 provides solid corrosion resistance across a broad range of fluids and a substantially lower installed weight compared to cast iron or steel female adapters of equivalent size — a meaningful field handling advantage when working with 6" pipe and fittings on large commercial and municipal installations.


Specifications:

Specification Detail
Part Number 435-060
Material PVC (Polyvinyl Chloride)
Schedule Schedule 40
Fitting Type Female Adapter
Size 6"
Connection Type Slip x FPT
Inlet Connection Slip (Socket — solvent weld)
Outlet Connection FPT (Female Pipe Thread)
Color White
Pressure Rating ~100 PSI @ 73°F
Temperature Range Up to 140°F (60°C)
Standard ASTM D1784, ASTM D2465
End Use Pressure Systems

⚠️ Note: Apply PTFE thread tape or PVC-compatible pipe dope to all male threads assembled into the FPT outlet before installation. Do not over-tighten threaded connections into the FPT outlet — large-diameter FPT ports are susceptible to body cracking under excessive torque or uneven loading from unsupported downstream pipe weight; support downstream pipe runs independently. Use primer on both the slip socket interior and the pipe end before cementing — do not skip the priming step at 6" diameter. A two-person assembly is recommended at this size. Consult manufacturer derating tables for elevated-temperature service.


Industries & Applications:

  • Municipal Water Distribution — Transitions 6" cemented PVC distribution mains to threaded equipment connections, isolation valves, and service fittings at points in the municipal distribution network where the cemented pipe system must interface with male-threaded valves, meters, or hydrant assemblies at full bore
  • Irrigation & Agricultural Systems — Used at pump station outlets, large manifold terminations, and control valve inlets on high-volume agricultural, golf course, and commercial irrigation systems where a 6" cemented supply main must connect to the threaded inlet of a large valve, filter, or pump equipment port
  • Water & Wastewater Treatment — Applied at the boundary between 6" cemented PVC distribution or process piping and the threaded inlet and outlet ports of treatment equipment — large filters, chemical injection points, flow meters, and pump assemblies — where the cemented pipe system terminates and the equipment connection begins
  • Industrial Process Piping — Installed at equipment connection points on 6" process water, cooling water, and non-aggressive chemical mains where the cemented PVC distribution system must interface with male-threaded equipment ports, valves, and instrumentation connections at full 6" bore
  • Pump Station & Equipment Connections — Connects 6" cemented PVC suction and discharge mains to the threaded inlet and outlet ports of large pump housings, creating the transition between the permanent cemented pipe assembly and the serviceable threaded equipment connection at each side of the pump
  • Stormwater & Drainage Infrastructure — Used at outfall structures, inlet connections, and control points on large-diameter PVC stormwater conveyance systems where the cemented pipe run must transition to a threaded connection at a structure, headwall, or inline control device
(No reviews yet)
Width:
7.19 (in)
Height:
5.75 (in)
Depth:
7.19 (in)
Condition:
New
Current Stock:
Adding to cart… The item has been added
Technical Specifications

The 6" Slip x FPT Schedule 40 PVC Female Adapter is made for durability, compatibility, and reliable performance in the most demanding water-handling systems. To ensure proper selection for your project, review the key technical features:

  • Nominal Size: 6"
  • Connection Type: Slip/Socket × Female Pipe Thread (FPT)
  • Material: Schedule 40 PVC
  • Color: White
  • SKU / Part Number: 435-060
  • Product Family: Schedule 40 PVC fittings
  • Max Service Temperature: 140°F (cold and moderate-temperature water systems)
  • Standards: Manufactured from PVC compound meeting ASTM D1784 requirements
  • Packaging: Carton Qty 4, Pallet Qty 192
  • Performance: Intended for low to moderate pressure and non-pressurized water distribution systems
Typical Applications

This large-diameter PVC female adapter is used anywhere a secure slip-to-thread connection is required, supporting high-flow pipelines across several residential, commercial, agricultural, and industrial settings:

  • Integrating threaded valves, meters, sensors, pumps, or specialty fittings into a 6" PVC mainline
  • Municipal water and high-volume distribution lines
  • Agricultural irrigation and pivot systems
  • Aquaculture and fishery tanks or raceways
  • Industrial processing and washdown systems
  • Commercial pool, fountain, and waterpark plumbing
  • Drainage and stormwater management systems
  • OEM skids and system builds that require hybrid slip-and-threaded connections
Installation & Handling Tips

Proper installation provides you with a long-lasting, leak-resistant connection — especially when working with large-diameter Schedule 40 fittings. Follow these guidelines for a secure and stress-free setup:

  • Clean and dry both the pipe and socket before priming.
  • Apply purple primer and solvent cement per the manufacturer’s instructions; fully seat the pipe with even pressure.
  • Use additional support if needed to keep the fitting aligned during solvent welding.
  • Support the pipeline so system weight and vibration are not carried by the adapter.
  • Use PTFE thread sealant on male threads; avoid petroleum-based pipe dopes.
  • Hand-tighten first, then finish with a strap wrench to prevent over-torquing.
  • Allow full cure time before pressure testing the line.
  • Note: not for use in compressed air or gas systems.
Why Choose Maxx Supply?

Maxx Supply gives you dependable access to high-quality Schedule 40 PVC fittings, including hard-to-find large-diameter adapters like this one. Customers count on Maxx for reliable inventory, expert guidance, and fast order fulfillment:

  • Consistent availability of large-diameter Schedule 40 fittings
  • Fast shipping for contractors, irrigation professionals, municipalities, and industrial buyers
  • Competitive pricing with bulk carton and pallet options
  • All fittings meet industry-standard ASTM requirements
  • Expert technical support to help confirm sizing and compatibility
 
 

The 435-060 is a 6" Schedule 40 PVC Female Adapter with a Slip x FPT configuration. This fitting transitions a cemented PVC pipe run to a threaded connection at the same nominal size — the slip socket accepts 6" PVC pipe for solvent cementing on the pipe side, while the Female Pipe Thread (FPT) outlet on the opposite end receives any male-threaded (MPT) fitting, valve, pump flange adapter, or equipment port of the same nominal size. No size reduction occurs; the female adapter is a same-size connection-type transition fitting, converting a permanent cemented pipe end into a serviceable threaded port at full bore.

The female adapter occupies a distinct and essential role in PVC pressure piping systems. Where a coupling joins two cemented pipe ends and a union provides a disassemblable break point within a cemented run, the female adapter is the boundary fitting — it terminates the cemented pipe system at a defined point and presents a threaded female port for connection to whatever threaded component, valve, or equipment lies downstream. Once the adapter is cemented to the pipe, the FPT outlet functions exactly as a threaded port would in any other context: it can receive and release male-threaded connections repeatedly without disturbing the cemented pipe assembly upstream.

At 6", the 435-060 is a large-format adapter sized for high-volume commercial and industrial piping applications. The 6" female adapter is most commonly encountered at the interface between large-diameter PVC distribution mains and the threaded inlets and outlets of major equipment — large pump housings, large ball valves or butterfly valves with threaded end connections, large filter vessels, flow meters, and storage tank ports — where the supply or distribution infrastructure is 6" cemented PVC and the equipment connection is male-threaded at the same nominal size. It also appears at flanged assemblies where a threaded nipple bridges the female adapter to a companion flange fitting, and at system endpoints where the 6" cemented main must terminate at a threaded isolation valve or equipment inlet.

The same-size configuration — 6" slip to 6" FPT — means no flow restriction occurs at the adapter. The full bore of the 6" pipe passes through the fitting unobstructed, and the FPT outlet presents the same nominal bore to the downstream connection. This distinguishes the female adapter from a reducing bushing (which changes size) and from a union (which provides disassembly within the pipe run) — the female adapter's sole function is the connection-type transition from cemented to threaded at the same pipe size.

At 6" diameter, the cemented slip socket requires careful solvent welding practice — thorough, even primer and cement coverage across the full socket interior and pipe end surface is essential given the significantly larger joint surface area at this size. A two-person assembly is recommended: one to apply cement and seat the pipe, one to hold alignment firmly through the full set period. Pipe must be inserted to full socket depth and held without rotation until the joint sets. Thread sealant tape (PTFE) or pipe dope rated for PVC service should be applied to all male threads assembled into the FPT outlet before installation, and downstream pipe or equipment weight should be supported independently rather than cantilevered from the adapter body.

Manufactured in white Schedule 40 PVC, the 435-060 provides solid corrosion resistance across a broad range of fluids and a substantially lower installed weight compared to cast iron or steel female adapters of equivalent size — a meaningful field handling advantage when working with 6" pipe and fittings on large commercial and municipal installations.


Specifications:

Specification Detail
Part Number 435-060
Material PVC (Polyvinyl Chloride)
Schedule Schedule 40
Fitting Type Female Adapter
Size 6"
Connection Type Slip x FPT
Inlet Connection Slip (Socket — solvent weld)
Outlet Connection FPT (Female Pipe Thread)
Color White
Pressure Rating ~100 PSI @ 73°F
Temperature Range Up to 140°F (60°C)
Standard ASTM D1784, ASTM D2465
End Use Pressure Systems

⚠️ Note: Apply PTFE thread tape or PVC-compatible pipe dope to all male threads assembled into the FPT outlet before installation. Do not over-tighten threaded connections into the FPT outlet — large-diameter FPT ports are susceptible to body cracking under excessive torque or uneven loading from unsupported downstream pipe weight; support downstream pipe runs independently. Use primer on both the slip socket interior and the pipe end before cementing — do not skip the priming step at 6" diameter. A two-person assembly is recommended at this size. Consult manufacturer derating tables for elevated-temperature service.


Industries & Applications:

  • Municipal Water Distribution — Transitions 6" cemented PVC distribution mains to threaded equipment connections, isolation valves, and service fittings at points in the municipal distribution network where the cemented pipe system must interface with male-threaded valves, meters, or hydrant assemblies at full bore
  • Irrigation & Agricultural Systems — Used at pump station outlets, large manifold terminations, and control valve inlets on high-volume agricultural, golf course, and commercial irrigation systems where a 6" cemented supply main must connect to the threaded inlet of a large valve, filter, or pump equipment port
  • Water & Wastewater Treatment — Applied at the boundary between 6" cemented PVC distribution or process piping and the threaded inlet and outlet ports of treatment equipment — large filters, chemical injection points, flow meters, and pump assemblies — where the cemented pipe system terminates and the equipment connection begins
  • Industrial Process Piping — Installed at equipment connection points on 6" process water, cooling water, and non-aggressive chemical mains where the cemented PVC distribution system must interface with male-threaded equipment ports, valves, and instrumentation connections at full 6" bore
  • Pump Station & Equipment Connections — Connects 6" cemented PVC suction and discharge mains to the threaded inlet and outlet ports of large pump housings, creating the transition between the permanent cemented pipe assembly and the serviceable threaded equipment connection at each side of the pump
  • Stormwater & Drainage Infrastructure — Used at outfall structures, inlet connections, and control points on large-diameter PVC stormwater conveyance systems where the cemented pipe run must transition to a threaded connection at a structure, headwall, or inline control device