Flange (Solid Style), Slip PVC Schedule 80 3" (851-030)
The 851-030 is a 3" Schedule 80 PVC Solid Style Flange with a Slip socket connection. Solid style flanges are one-piece, fixed-face fittings — the flange ring and socket body are permanently integrated into a single unit, providing a rigid, non-rotating connection point for bolting directly to pumps, valves, tank outlets, flow meters, strainers, and other flanged equipment or mating flange assemblies. The slip socket accepts standard 3" PVC pipe for solvent cementing on the pipe side, forming a permanent, pressure-rated bond that integrates the flange into the cemented pipe system. The flat flange face then presents a standard ANSI Class 150 bolt pattern for hardware connection to any compatible mating flange.
The solid style flange is a one-piece fixed assembly — this is its defining characteristic relative to the Van Stone loose ring flange (856-030FT, 854-030FT). Where the Van Stone design uses a two-piece rotating ring and stub end configuration that allows bolt hole alignment without rotating the pipe, the solid style flange is a single bonded unit in which the bolt holes are in a fixed position relative to the pipe socket. Once the slip socket is cemented to the pipe, the bolt hole orientation is permanently established and cannot be adjusted without cutting the pipe and re-cementing at a different rotational angle. For installations where bolt hole alignment can be set during the cement cure period — before the joint is fully hardened — the solid style flange is a clean, compact, reliable single-piece solution. For installations where post-cement bolt hole alignment is a practical requirement, the Van Stone flange is the appropriate alternative.
The solid style flange's single-piece construction is its primary advantage in terms of simplicity and assembly confidence. There is no backing ring to source, track, or position separately; no stub end-to-ring interface to manage; and no risk of the ring being omitted or incorrectly assembled during installation. The flange is solvent cemented to the pipe exactly as any other slip-socket fitting would be, and the result is a fully integrated, permanent flanged termination point ready for gasket and bolt assembly.
A full-face or ring gasket should be seated against the flat flange face before bolting, and bolts should be torqued evenly in a cross pattern to manufacturer specifications. At 3", PVC flange bolt torque is lower than equivalent metal flange assemblies — do not apply metal flange torque values to PVC flanges, and do not use impact tools for final torque. The flat face of the solid style flange is the sealing surface; uneven bolt loading or over-torquing will crack the flange face and require full replacement of the fitting and the cemented pipe section behind it.
At 3", the 851-030 is sized for mid-to-large commercial and industrial applications — pump stations, chemical processing lines, water treatment plant piping, and municipal utility infrastructure where 3" PVC is a primary pipe size and bolted flanged connections are required at equipment interfaces, valve stations, and system access points. Schedule 80 wall thickness ensures the fitting meets the pressure and chemical resistance demands of industrial service environments, and the dark gray rigid PVC compound provides broad resistance to acids, bases, and industrial chemicals throughout the service life of the installation.
Specifications:
| Specification | Detail |
|---|---|
| Part Number | 851-030 |
| Material | PVC (Polyvinyl Chloride) |
| Schedule | Schedule 80 |
| Fitting Type | Solid Style Flange |
| Size | 3" |
| Connection Type | Slip (Socket) |
| Flange Face | Flat Face |
| Bolt Pattern | ANSI Class 150 |
| Color | Dark Gray |
| Pressure Rating | 150 PSI @ 73°F |
| Temperature Range | Up to 140°F (60°C) |
| Standard | ASTM D1784, ASTM D2467 |
| End Use | Pressure Systems |
⚠️ Note: Pressure ratings decrease at elevated temperatures. Use a compatible full-face gasket and torque bolts evenly in a cross pattern to manufacturer specifications — do not apply metal flange torque values to PVC flanges and do not use impact tools for final torque. The bolt hole orientation is fixed once the slip socket is cemented — confirm correct rotational alignment before the joint fully cures. Never over-torque; the flat face is the sealing surface and is susceptible to cracking under uneven or excessive bolt load. Consult manufacturer derating tables for elevated-temperature service.
Industries & Applications:
- Water & Wastewater Treatment — Provides permanent, bolt-up flanged connection points on 3" Schedule 80 PVC pump inlet and outlet piping, filter assemblies, and treatment equipment interfaces at plant facilities where corrosion-resistant materials are required throughout and bolt hole alignment can be established during installation before the cemented joint fully cures
- Chemical Processing — Used at equipment tie-in points on 3" chemical distribution and process lines where a permanent, single-piece flanged termination is preferred for its simplicity and assembly integrity over a two-piece Van Stone assembly, and where the fixed bolt hole orientation is not a constraint because equipment alignment is established before cementing
- Industrial Process Piping — Provides flanged connection points on 3" process water, cooling water, and chemical lines at process skid equipment interfaces, valve stations, and instrumentation flanges where the one-piece solid flange delivers a clean, reliable bolted joint without the additional components of a Van Stone assembly
- Pump Station & Equipment Connections — Installed on 3" pump discharge and suction lines where a permanent, solid-body flanged connection to the pump housing, discharge valve, or connecting header provides a robust equipment interface that is simpler to assemble and inspect than a multi-piece Van Stone flange at the same connection point
- Municipal & Utility Infrastructure — Applied on 3" municipal water distribution mains, pump station headers, and valve vault assemblies where solid style flanges provide permanent, pressure-rated bolted connection points to valves, meters, and equipment at defined service and access points in the distribution system
- Irrigation & Agricultural Systems — Connects 3" cemented PVC supply mains to flanged pump equipment, large valve bodies, and flow metering devices on high-volume irrigation systems where the one-piece solid flange provides a straightforward, dependable bolted equipment interface without the complexity of a two-piece Van Stone assembly
The 851-030 is a 3" Schedule 80 PVC Solid Style Flange with a Slip socket connection. Solid style flanges are one-piece, fixed-face fittings — the flange ring and socket body are permanently integrated into a single unit, providing a rigid, non-rotating connection point for bolting directly to pumps, valves, tank outlets, flow meters, strainers, and other flanged equipment or mating flange assemblies. The slip socket accepts standard 3" PVC pipe for solvent cementing on the pipe side, forming a permanent, pressure-rated bond that integrates the flange into the cemented pipe system. The flat flange face then presents a standard ANSI Class 150 bolt pattern for hardware connection to any compatible mating flange.
The solid style flange is a one-piece fixed assembly — this is its defining characteristic relative to the Van Stone loose ring flange (856-030FT, 854-030FT). Where the Van Stone design uses a two-piece rotating ring and stub end configuration that allows bolt hole alignment without rotating the pipe, the solid style flange is a single bonded unit in which the bolt holes are in a fixed position relative to the pipe socket. Once the slip socket is cemented to the pipe, the bolt hole orientation is permanently established and cannot be adjusted without cutting the pipe and re-cementing at a different rotational angle. For installations where bolt hole alignment can be set during the cement cure period — before the joint is fully hardened — the solid style flange is a clean, compact, reliable single-piece solution. For installations where post-cement bolt hole alignment is a practical requirement, the Van Stone flange is the appropriate alternative.
The solid style flange's single-piece construction is its primary advantage in terms of simplicity and assembly confidence. There is no backing ring to source, track, or position separately; no stub end-to-ring interface to manage; and no risk of the ring being omitted or incorrectly assembled during installation. The flange is solvent cemented to the pipe exactly as any other slip-socket fitting would be, and the result is a fully integrated, permanent flanged termination point ready for gasket and bolt assembly.
A full-face or ring gasket should be seated against the flat flange face before bolting, and bolts should be torqued evenly in a cross pattern to manufacturer specifications. At 3", PVC flange bolt torque is lower than equivalent metal flange assemblies — do not apply metal flange torque values to PVC flanges, and do not use impact tools for final torque. The flat face of the solid style flange is the sealing surface; uneven bolt loading or over-torquing will crack the flange face and require full replacement of the fitting and the cemented pipe section behind it.
At 3", the 851-030 is sized for mid-to-large commercial and industrial applications — pump stations, chemical processing lines, water treatment plant piping, and municipal utility infrastructure where 3" PVC is a primary pipe size and bolted flanged connections are required at equipment interfaces, valve stations, and system access points. Schedule 80 wall thickness ensures the fitting meets the pressure and chemical resistance demands of industrial service environments, and the dark gray rigid PVC compound provides broad resistance to acids, bases, and industrial chemicals throughout the service life of the installation.
Specifications:
| Specification | Detail |
|---|---|
| Part Number | 851-030 |
| Material | PVC (Polyvinyl Chloride) |
| Schedule | Schedule 80 |
| Fitting Type | Solid Style Flange |
| Size | 3" |
| Connection Type | Slip (Socket) |
| Flange Face | Flat Face |
| Bolt Pattern | ANSI Class 150 |
| Color | Dark Gray |
| Pressure Rating | 150 PSI @ 73°F |
| Temperature Range | Up to 140°F (60°C) |
| Standard | ASTM D1784, ASTM D2467 |
| End Use | Pressure Systems |
⚠️ Note: Pressure ratings decrease at elevated temperatures. Use a compatible full-face gasket and torque bolts evenly in a cross pattern to manufacturer specifications — do not apply metal flange torque values to PVC flanges and do not use impact tools for final torque. The bolt hole orientation is fixed once the slip socket is cemented — confirm correct rotational alignment before the joint fully cures. Never over-torque; the flat face is the sealing surface and is susceptible to cracking under uneven or excessive bolt load. Consult manufacturer derating tables for elevated-temperature service.
Industries & Applications:
- Water & Wastewater Treatment — Provides permanent, bolt-up flanged connection points on 3" Schedule 80 PVC pump inlet and outlet piping, filter assemblies, and treatment equipment interfaces at plant facilities where corrosion-resistant materials are required throughout and bolt hole alignment can be established during installation before the cemented joint fully cures
- Chemical Processing — Used at equipment tie-in points on 3" chemical distribution and process lines where a permanent, single-piece flanged termination is preferred for its simplicity and assembly integrity over a two-piece Van Stone assembly, and where the fixed bolt hole orientation is not a constraint because equipment alignment is established before cementing
- Industrial Process Piping — Provides flanged connection points on 3" process water, cooling water, and chemical lines at process skid equipment interfaces, valve stations, and instrumentation flanges where the one-piece solid flange delivers a clean, reliable bolted joint without the additional components of a Van Stone assembly
- Pump Station & Equipment Connections — Installed on 3" pump discharge and suction lines where a permanent, solid-body flanged connection to the pump housing, discharge valve, or connecting header provides a robust equipment interface that is simpler to assemble and inspect than a multi-piece Van Stone flange at the same connection point
- Municipal & Utility Infrastructure — Applied on 3" municipal water distribution mains, pump station headers, and valve vault assemblies where solid style flanges provide permanent, pressure-rated bolted connection points to valves, meters, and equipment at defined service and access points in the distribution system
- Irrigation & Agricultural Systems — Connects 3" cemented PVC supply mains to flanged pump equipment, large valve bodies, and flow metering devices on high-volume irrigation systems where the one-piece solid flange provides a straightforward, dependable bolted equipment interface without the complexity of a two-piece Van Stone assembly
- Part #:
- 851-030
- Product Family:
- Sch 80 PVC
- Carton Qty:
- 5
- Pallet Qty:
- 500
- Size:
- 3"