Plug, Spigot PVC Schedule 40 1-1/2" (449-015)

SKU:
449-015
|
UPC:
25528719180
Availability:
Typically ships within 24 hrs
$1.56

This 1-1/2" Schedule 40 PVC Spigot Plug provides a permanent, solvent-cemented closure for any open 1-1/2" female slip socket port in a Schedule 40 PVC pressure piping system. The spigot end — a male plain end with an OD matching standard 1-1/2" PVC pipe — inserts directly into a 1-1/2" female slip socket opening for solvent cement joining, sealing the port from the inside with a fused, pressure-rated closure that becomes an integral part of the fitting body once cured.

At 1-1/2", the spigot plug serves one of the most prevalent pipe sizes across residential and commercial Schedule 40 systems. Secondary distribution headers, pump suction and discharge manifolds, pool and spa recirculation mains, irrigation submain distribution assemblies, equipment feed connections, and primary branch supply mains throughout residential, commercial, and light industrial facilities regularly include tees, crosses, wyes, and manifold fittings at 1-1/2" with spare or unused socket ports. The 449-015 is the most direct permanent closure available at these 1-1/2" socket positions — a single spigot inserted and cemented into the open socket, accomplishing the complete closure in one fitting and one joint at the port face.

Selecting the 449-015 correctly at a 1-1/2" port requires identifying both the port connection type and the permanence requirement. The 449-015 closes open slip socket ports by inserting into them from the inside — the male spigot seats within the socket bore and is held permanently by the solvent-cemented joint. This distinguishes it from the 450-015 MPT plug (previously written at the same size), which closes female-threaded (FPT) ports by threading into them and can be removed at any time. At the same 1-1/2" pipe size, both closure types may be required in the same system at different port positions: the spigot plug at unused slip socket outlets on solvent-welded tees and couplings; the MPT plug at unused FPT branch ports on threaded fittings and equipment bodies. Neither can substitute for the other — the port connection type determines which is correct. The 448-series FPT cap adds a third option at 1-1/2" for closing male-threaded nipple and pipe ends rather than female ports.

The permanence of the spigot plug joint is the appropriate design choice wherever the socket port is genuinely terminal — spare tee branch sockets in completed irrigation submain layouts that will not be extended during the system's service life, unused cross outlets on pool recirculation headers in final configuration, wye branch sockets in drain systems at permanently terminal positions, and any slip socket opening where future access is neither planned nor required. Permanent closure produces a cemented joint that is as strong as or stronger than the surrounding pipe once cured — the sealed port presents no weak point, no potential leak path, and no future maintenance requirement at the closure position.

Where future access at the socket port is possible — for planned zone additions, seasonal equipment changes, or system expansion — the serviceable alternative is to install a Schedule 40 female adapter into the socket and close it with a removable 450-015 MPT plug, preserving the option to reopen the port without cutting. The 449-015 is for socket ports where that flexibility is not required.

The Schedule 40 designation distinguishes this plug from the 849-015 Schedule 80 spigot plug at the same fitting function and port orientation. The 849-015 serves Schedule 80 slip socket systems at a higher pressure rating in dark gray PVC; the 449-015 is the correct selection for Schedule 40 white PVC socket systems where the Schedule 40 pressure rating is sufficient for the application. Using a Schedule 40 spigot plug in a Schedule 40 socket system preserves pressure rating consistency at the closed port.

Manufactured in white Schedule 40 PVC, this plug delivers reliable performance across residential, commercial, and light industrial piping applications. PVC's resistance to acids, bases, salts, chlorine, and common process fluids provides long service life where metal plugs would corrode, pit, or contaminate the fluid stream at socket closure positions. NSF/ANSI 61 and NSF/ANSI 14 listings confirm suitability for potable water contact.

Rated to 280 psi at 73°F, this plug handles standard pressure service across irrigation, commercial plumbing, pool and spa, water treatment, and light industrial applications at 1-1/2". For installation, clean and dry the spigot exterior and receiving socket interior thoroughly before application. Apply purple PVC primer to both mating surfaces — the full spigot end and the full socket bore — then apply a uniform coat of Schedule 40 PVC solvent cement to both surfaces before inserting. Push the spigot fully into the socket with a slight quarter-turn twist and hold firmly for 30 seconds to prevent pushback while the cement sets. Allow full cure time per the cement manufacturer's temperature and humidity guidelines before pressurizing the system. Apply published pressure derating factors for service temperatures above 73°F.


Specifications:

Attribute Detail
Part Number 449-015
Fitting Type Plug
Connection Type Spigot (Male Plain End — solvent cement)
Size 1-1/2"
Schedule / Series Schedule 40
Material PVC (Polyvinyl Chloride)
Color White
Pressure Rating 280 psi @ 73°F (verify vs. manufacturer data sheet)
ASTM Standard D2466
NSF/ANSI NSF/ANSI 61 & NSF/ANSI 14 Listed
Temperature Range Up to 140°F (derate pressure for elevated temps)
End Configuration Single spigot end; opposite end permanently closed
Closure Type Permanent (solvent-cemented — not removable without cutting)
Port Closed 1-1/2" female slip socket ports (FPT threaded ports require MPT plug — 450-series; MPT pipe ends require FPT cap — 448-series)
Solvent Cement Standard Schedule 40 PVC cement; primer required

Industries & Applications:

  • Tee, Cross & Wye Branch Socket Sealing — Permanently closes unused 1-1/2" female slip socket branch outlets on Schedule 40 tees, crosses, wyes, and manifold assemblies in irrigation, pool and spa, commercial plumbing, and light industrial piping — the primary application for the 449-015 across all system types; the spigot inserts directly into the open socket and cements in place as a single fitting, producing the most compact and lowest-joint-count permanent closure available at a 1-1/2" socket position
  • Commercial & Residential Irrigation — Permanently seals unused 1-1/2" slip socket branch outlets on submain distribution tees, manifold fitting sockets, zone header crosses, and coupling socket outlets in residential and commercial irrigation systems where spare socket ports are included in the submain layout for future zone additions and are permanently closed when the system reaches final configuration or zone expansion is not anticipated
  • Pool, Spa & Aquaculture — Closes unused 1-1/2" slip socket ports on recirculation header tees, filter manifold socket outlets, backwash header branch sockets, and equipment header cross fittings in commercial and residential pool, spa, and aquatic facility installations where spare socket positions in the primary 1-1/2" recirculation and distribution piping are permanently sealed when not required by the system design
  • Commercial Plumbing — Permanently seals unused 1-1/2" slip socket branch outlets on distribution tees, manifold assembly sockets, and coupling outlets in commercial building water supply and mechanical room Schedule 40 systems where terminal socket positions require permanent closure and no future access is planned at the sealed port
  • System Commissioning & Pressure Testing — Provides a permanent, schedule-consistent closure at open 1-1/2" slip socket positions during hydrostatic and pneumatic pressure testing of Schedule 40 PVC piping systems in residential and commercial construction — ensuring the plug does not limit test pressure at socket closure positions and maintaining Schedule 40 pressure rating continuity at the terminal socket joint
  • Water & Wastewater Treatment — Seals decommissioned and spare 1-1/2" slip socket branch connections, unused secondary distribution sockets, and spare manifold outlets on Schedule 40 PVC process piping in municipal and industrial water treatment facilities where permanent socket closure is the correct specification for terminal branch positions in the process piping layout
  • Gravity Drain & DWV Systems — Permanently closes unused 1-1/2" slip socket branch outlets on DWV tees, wyes, and cleanout fittings in residential and commercial building drain systems where the branch socket position is sealed at construction and not anticipated to be reopened during the service life of the drain system
(No reviews yet)
Width:
2.16 (in)
Height:
1.63 (in)
Depth:
2.16 (in)
Condition:
New
Current Stock:
Adding to cart… The item has been added

This 1-1/2" Schedule 40 PVC Spigot Plug provides a permanent, solvent-cemented closure for any open 1-1/2" female slip socket port in a Schedule 40 PVC pressure piping system. The spigot end — a male plain end with an OD matching standard 1-1/2" PVC pipe — inserts directly into a 1-1/2" female slip socket opening for solvent cement joining, sealing the port from the inside with a fused, pressure-rated closure that becomes an integral part of the fitting body once cured.

At 1-1/2", the spigot plug serves one of the most prevalent pipe sizes across residential and commercial Schedule 40 systems. Secondary distribution headers, pump suction and discharge manifolds, pool and spa recirculation mains, irrigation submain distribution assemblies, equipment feed connections, and primary branch supply mains throughout residential, commercial, and light industrial facilities regularly include tees, crosses, wyes, and manifold fittings at 1-1/2" with spare or unused socket ports. The 449-015 is the most direct permanent closure available at these 1-1/2" socket positions — a single spigot inserted and cemented into the open socket, accomplishing the complete closure in one fitting and one joint at the port face.

Selecting the 449-015 correctly at a 1-1/2" port requires identifying both the port connection type and the permanence requirement. The 449-015 closes open slip socket ports by inserting into them from the inside — the male spigot seats within the socket bore and is held permanently by the solvent-cemented joint. This distinguishes it from the 450-015 MPT plug (previously written at the same size), which closes female-threaded (FPT) ports by threading into them and can be removed at any time. At the same 1-1/2" pipe size, both closure types may be required in the same system at different port positions: the spigot plug at unused slip socket outlets on solvent-welded tees and couplings; the MPT plug at unused FPT branch ports on threaded fittings and equipment bodies. Neither can substitute for the other — the port connection type determines which is correct. The 448-series FPT cap adds a third option at 1-1/2" for closing male-threaded nipple and pipe ends rather than female ports.

The permanence of the spigot plug joint is the appropriate design choice wherever the socket port is genuinely terminal — spare tee branch sockets in completed irrigation submain layouts that will not be extended during the system's service life, unused cross outlets on pool recirculation headers in final configuration, wye branch sockets in drain systems at permanently terminal positions, and any slip socket opening where future access is neither planned nor required. Permanent closure produces a cemented joint that is as strong as or stronger than the surrounding pipe once cured — the sealed port presents no weak point, no potential leak path, and no future maintenance requirement at the closure position.

Where future access at the socket port is possible — for planned zone additions, seasonal equipment changes, or system expansion — the serviceable alternative is to install a Schedule 40 female adapter into the socket and close it with a removable 450-015 MPT plug, preserving the option to reopen the port without cutting. The 449-015 is for socket ports where that flexibility is not required.

The Schedule 40 designation distinguishes this plug from the 849-015 Schedule 80 spigot plug at the same fitting function and port orientation. The 849-015 serves Schedule 80 slip socket systems at a higher pressure rating in dark gray PVC; the 449-015 is the correct selection for Schedule 40 white PVC socket systems where the Schedule 40 pressure rating is sufficient for the application. Using a Schedule 40 spigot plug in a Schedule 40 socket system preserves pressure rating consistency at the closed port.

Manufactured in white Schedule 40 PVC, this plug delivers reliable performance across residential, commercial, and light industrial piping applications. PVC's resistance to acids, bases, salts, chlorine, and common process fluids provides long service life where metal plugs would corrode, pit, or contaminate the fluid stream at socket closure positions. NSF/ANSI 61 and NSF/ANSI 14 listings confirm suitability for potable water contact.

Rated to 280 psi at 73°F, this plug handles standard pressure service across irrigation, commercial plumbing, pool and spa, water treatment, and light industrial applications at 1-1/2". For installation, clean and dry the spigot exterior and receiving socket interior thoroughly before application. Apply purple PVC primer to both mating surfaces — the full spigot end and the full socket bore — then apply a uniform coat of Schedule 40 PVC solvent cement to both surfaces before inserting. Push the spigot fully into the socket with a slight quarter-turn twist and hold firmly for 30 seconds to prevent pushback while the cement sets. Allow full cure time per the cement manufacturer's temperature and humidity guidelines before pressurizing the system. Apply published pressure derating factors for service temperatures above 73°F.


Specifications:

Attribute Detail
Part Number 449-015
Fitting Type Plug
Connection Type Spigot (Male Plain End — solvent cement)
Size 1-1/2"
Schedule / Series Schedule 40
Material PVC (Polyvinyl Chloride)
Color White
Pressure Rating 280 psi @ 73°F (verify vs. manufacturer data sheet)
ASTM Standard D2466
NSF/ANSI NSF/ANSI 61 & NSF/ANSI 14 Listed
Temperature Range Up to 140°F (derate pressure for elevated temps)
End Configuration Single spigot end; opposite end permanently closed
Closure Type Permanent (solvent-cemented — not removable without cutting)
Port Closed 1-1/2" female slip socket ports (FPT threaded ports require MPT plug — 450-series; MPT pipe ends require FPT cap — 448-series)
Solvent Cement Standard Schedule 40 PVC cement; primer required

Industries & Applications:

  • Tee, Cross & Wye Branch Socket Sealing — Permanently closes unused 1-1/2" female slip socket branch outlets on Schedule 40 tees, crosses, wyes, and manifold assemblies in irrigation, pool and spa, commercial plumbing, and light industrial piping — the primary application for the 449-015 across all system types; the spigot inserts directly into the open socket and cements in place as a single fitting, producing the most compact and lowest-joint-count permanent closure available at a 1-1/2" socket position
  • Commercial & Residential Irrigation — Permanently seals unused 1-1/2" slip socket branch outlets on submain distribution tees, manifold fitting sockets, zone header crosses, and coupling socket outlets in residential and commercial irrigation systems where spare socket ports are included in the submain layout for future zone additions and are permanently closed when the system reaches final configuration or zone expansion is not anticipated
  • Pool, Spa & Aquaculture — Closes unused 1-1/2" slip socket ports on recirculation header tees, filter manifold socket outlets, backwash header branch sockets, and equipment header cross fittings in commercial and residential pool, spa, and aquatic facility installations where spare socket positions in the primary 1-1/2" recirculation and distribution piping are permanently sealed when not required by the system design
  • Commercial Plumbing — Permanently seals unused 1-1/2" slip socket branch outlets on distribution tees, manifold assembly sockets, and coupling outlets in commercial building water supply and mechanical room Schedule 40 systems where terminal socket positions require permanent closure and no future access is planned at the sealed port
  • System Commissioning & Pressure Testing — Provides a permanent, schedule-consistent closure at open 1-1/2" slip socket positions during hydrostatic and pneumatic pressure testing of Schedule 40 PVC piping systems in residential and commercial construction — ensuring the plug does not limit test pressure at socket closure positions and maintaining Schedule 40 pressure rating continuity at the terminal socket joint
  • Water & Wastewater Treatment — Seals decommissioned and spare 1-1/2" slip socket branch connections, unused secondary distribution sockets, and spare manifold outlets on Schedule 40 PVC process piping in municipal and industrial water treatment facilities where permanent socket closure is the correct specification for terminal branch positions in the process piping layout
  • Gravity Drain & DWV Systems — Permanently closes unused 1-1/2" slip socket branch outlets on DWV tees, wyes, and cleanout fittings in residential and commercial building drain systems where the branch socket position is sealed at construction and not anticipated to be reopened during the service life of the drain system
Part #:
449-015
Product Family:
Sch 40 PVC
Size:
1-1/2"