Reducing Tee, Slip x Slip x Slip PVC Schedule 80 12" x 12" x 8" (801-668)
The 12" x 12" x 8" Schedule 80 Gray PVC Reducing Tee (801-668, Slip x Slip x Slip) is a large-diameter, heavy-wall specialty tee fitting manufactured to ASTM D2467 in Schedule 80 gray PVC — a reducing tee configuration in which the run connections are 12" and the branch connection is 8", providing a single-body Schedule 80 PVC solution for taking a major 8" branch connection off a 12" primary main without reducing the primary flow path diameter, without field-fabricated saddle taps or custom manifold assemblies, and without transitioning out of Schedule 80 gray PVC construction at the branch takeoff point. In a reducing tee, flow through the 12" run continues uninterrupted through the straight-run ports while the 8" branch connection provides a perpendicular takeoff for major zone supply, high-volume equipment feed, large parallel system connection, or primary sector distribution — the correct large-diameter primary main branch geometry for systems where the 12" primary transmission or distribution main must supply an 8" branch connection that carries a substantial portion of the primary flow to treatment equipment, distribution zones, pump station branches, or parallel process lines while maintaining the full 12" flow path between the tee's run ports.
The 12" x 12" x 8" configuration occupies a distinct position in the large-diameter Schedule 80 PVC reducing tee series that is meaningfully different from both the 12" x 12" x 6" configuration (801-666) and the 12" equal tee (801-120). The 8" branch at 68% of the 12" run diameter is a major branch takeoff — not the relatively modest lateral connection that the 6" branch on the 801-666 represents, and not the equal-diameter three-way split of the 801-120, but a high-volume branch connection serving a system whose branch flow requirements have been engineered at 8" precisely because the zone, sector, or parallel system being supplied demands a branch capacity substantially greater than a 6" connection can provide without unacceptable flow restriction, velocity increase, or pressure loss at the branch entry. In the hydraulic design logic of large-diameter primary PVC systems, the choice between a 6" and an 8" branch off a 12" run reflects a branch flow analysis — the 8" branch is specified where the branch zone or sector carries 40% to 60% of the primary main's full flow capacity, where a 6" branch would create unacceptable pressure loss and velocity at the branch entry under peak flow conditions, and where the hydraulic engineer has determined that the branch pipe must be 8" to maintain the pressure and flow rate the downstream distribution system requires. For commercial irrigation engineers, municipal water system civil engineers, industrial process piping mechanical engineers, and water treatment plant design engineers specifying this branch flow profile on 12" primary mains, the 801-668 is the catalog Schedule 80 PVC fitting that provides the manufactured, rated, specification-compliant single-body solution for the 12" primary to 8" major branch takeoff that cannot be served by the 801-666's 6" branch or the 801-120's equal 12" branch.
Schedule 80 gray PVC construction is the correct and only material specification for this fitting across every application where the 12" x 12" x 8" reducing tee configuration is required. The Schedule 80 wall thickness at both the 12" run and the 8" branch dimensions provides the structural integrity, pressure performance, and mechanical robustness required at a 12" primary main branch connection of this scale and branch size — where internal pressure forces are at the maximum of the commercial PVC fitting line, where the 8" branch entry hydraulic forces subject the tee body to a greater lateral loading than the 6" branch configuration because of the larger branch port area and the higher branch flow volume, and where the fitting must support the combined weight, thermal movement, and operational vibration of connected 12" primary main pipe runs and an 8" branch pipe run simultaneously at the primary manifold location. The gray color provides permanent, inspectable Schedule 80 material class identification at the primary main 8" branch connection — the critical fitting location where material class confirmation is required for system commissioning, AHJ inspection sign-off, and long-term infrastructure asset management documentation. PVC Type 1 Grade 1 construction with cell classification 12454 per ASTM D1784 provides broad chemical resistance across water treatment chemicals, process water service, industrial utility water, and the full range of non-solvent process fluids appropriate for Schedule 80 PVC primary main service. All three socket ends solvent cement directly onto standard IPS Schedule 40 or Schedule 80 PVC pipe of the corresponding nominal sizes — 12" IPS schedule pipe on both run ports and 8" IPS schedule pipe on the branch port. At the 12" socket connections in particular, joint assembly is the most technically demanding in the commercial Schedule 80 PVC fitting line: heavy-body solvent cement rated for large-diameter Schedule 80 PVC is mandatory at all three connections, pre-planned assembly with all components accessible and positioned before cement application begins is essential, full circumferential heavy-body cement coverage across the complete bonding surface of each pipe end and fitting socket must be achieved at both the 12" run sockets and the 8" branch socket, and full cure time compliance before any system pressurization is non-negotiable at this primary main connection where partial cure under system pressure carries the most severe operational and infrastructure consequences in the commercial PVC fitting line.
NSF 61 certification lists this fitting for potable water contact, and NSF 14 covers compliance with applicable plastics piping material standards — making it the correct primary main branch fitting for municipal water treatment and distribution systems, large potable water pump station distribution headers, and large commercial and institutional water supply primary mains where NSF-listed materials are required at every fitting in the primary distribution system. ASTM D2467 governs Schedule 80 PVC socket fittings and defines the manufacturing, dimensional, and pressure performance requirements the 801-668 is produced to. Verify manufacturer pressure rating documentation for the specific fitting configuration before final system specification — at the 12" x 12" x 8" reducing tee configuration, the governing pressure rating is determined by the largest port size (12") and the fitting's tested performance at this large-diameter reducing geometry with an 8" branch, and must be confirmed against the manufacturer's published pressure-temperature rating table for SKU 801-668 before installation in systems at or near the fitting's rated pressure ceiling.
Key Features:
- Schedule 80 gray PVC reducing tee — 12" x 12" run x 8" branch, all socket (slip) ends
- Reducing configuration — major 8" branch takeoff off 12" primary run with full 12" straight-run flow path maintained
- 8" branch at 68% of run diameter — serves high-volume zone supply, major parallel system connections, and sector distribution branches requiring greater capacity than a 6" branch provides
- Manufactured to ASTM D2467 — the governing standard for Schedule 80 PVC socket fittings
- NSF 61 certified for potable water contact; NSF 14 listed
- Solvent cement socket connections compatible with Schedule 40 and Schedule 80 IPS pipe at both run and branch sizes
- Gray color — universal Schedule 80 material class identification at the primary main branch connection
- Single-body fitting solution for 12" primary main to 8" major branch takeoff — eliminates field-fabricated saddle taps and custom manifold assemblies
- Cell classification PVC 12454 per ASTM D1784
- Heavy-body solvent cement required at all three socket connections; full cure time compliance mandatory before pressurization
- Pressure rating: verify against manufacturer pressure-temperature table for SKU 801-668
Specifications:
| Attribute | Value |
|---|---|
| SKU | 801-668 |
| Fitting Type | Reducing Tee |
| Run Size | 12" x 12" |
| Branch Size | 8" |
| End Connections | Slip x Slip x Slip (All Socket) |
| Connection Method | Solvent Cement (IPS) |
| Compatible Pipe — Run | 12" IPS Schedule 40 or Schedule 80 PVC |
| Compatible Pipe — Branch | 8" IPS Schedule 40 or Schedule 80 PVC |
| Schedule | Schedule 80 |
| Material | PVC (Polyvinyl Chloride) Type 1, Grade 1 |
| Cell Classification | 12454 per ASTM D1784 |
| Color | Gray |
| Manufacturing Standard | ASTM D2467 |
| Potable Water Certification | NSF/ANSI 61 |
| Plastics Standard Certification | NSF 14 |
| Max Service Temperature | 140°F (60°C) |
| Pressure Rating | Verify with manufacturer pressure-temperature rating table for SKU 801-668 |
Industries & Applications:
- Municipal Water Distribution — Primary Transmission Main Major Branch Connections — The 12" x 12" x 8" reducing tee is specified at high-volume 8" branch takeoff points on 12" municipal water transmission and primary distribution mains — connections supplying 8" primary zone transmission laterals, major pressure zone supply headers, large-diameter fire flow supply mains, and high-volume sector distribution branches where the branch flow requirement at the 12" primary main junction demands a full 8" port that the 801-666's 6" branch cannot serve without unacceptable pressure loss and velocity at the branch entry under peak demand conditions; at municipal scale, every branch connection fitting on a 12" primary transmission main is a formally specified, permitted, and inspected infrastructure component — the 801-668 provides the manufactured, rated, NSF-listed, ASTM D2467-compliant single-body Schedule 80 PVC solution for the high-volume 8" branch connection requirement at primary transmission main junction points in large municipal PVC water distribution system construction where the branch flow analysis has established 8" as the correct branch pipe size
- Water Treatment Plant — Primary Header Major Branch Connections — Installed at high-volume 8" branch connection points on 12" primary distribution headers in municipal and industrial water treatment plants — clearwell supply and distribution primary trunks supplying major 8" zone distribution headers, filter influent and effluent primary headers branching to large parallel filter train supply connections, backwash primary supply mains connecting to 8" backwash equipment headers, and plant service water primary headers supplying 8" major equipment supply branches; the 8" branch configuration is specified at water treatment plant primary header locations where the branch serves a major equipment train or distribution zone with flow requirements that exceed the capacity of a 6" branch connection and approach the capacity of the 8" service pipe size; NSF 61 listing makes this fitting appropriate for every potable water treatment primary distribution major branch connection, and Schedule 80 gray PVC construction satisfies the material class and pressure performance requirements at these large-diameter primary header branch connection locations
- Pump Station — Primary Header to Major Branch Supply Connections — Used at 8" major branch supply connections off 12" primary pump station headers in large pump stations, booster pump stations, municipal well field pump stations, and water storage facility pump rooms where the 12" primary pump discharge or suction header must supply an 8" branch connection to a major pump train, a high-volume pressure zone supply connection, a parallel pump station primary header, or a large-capacity zone isolation valve assembly; the 8" branch at pump station primary header level is the correct specification where the branch serves a pump unit or zone with output or supply requirements that a 6" branch connection would restrict under full pump station operating conditions; at primary pump station header branch connections of this scale, the 801-668 is the single-body Schedule 80 PVC fitting that provides a manufactured, rated, code-compliant 8" branch connection without field-fabricated configurations that introduce additional leak points and material class documentation complications at the most hydraulically active location in the pump station piping
- Industrial Process Piping — Primary Header High-Volume Branch Takeoffs — Used at high-volume 8" branch takeoff points on 12" process water primary headers, cooling water primary distribution trunks, plant utility water primary mains, and large-volume industrial process fluid primary distribution headers in manufacturing plants, chemical processing facilities, petrochemical support facilities, and heavy industrial environments where the 12" primary process header must supply an 8" branch to a major equipment section, a high-flow process unit, a large parallel distribution system, or a primary sector supply header carrying a substantial portion of the primary header flow; the 8" branch configuration is specified at industrial primary header locations where the branch flow analysis establishes 8" as the correct branch pipe size — where the downstream process section demand exceeds what a 6" branch can supply without pressure and velocity penalties and where a full equal 12" branch is more than the branch section requires; Schedule 80 gray PVC construction provides the chemical resistance, structural wall thickness, and material class documentation required at large-diameter primary header branch connections in industrial process piping systems
- Large Commercial & Agricultural Irrigation — Primary Trunk Major Zone Branch Connections — Specified at high-volume 8" branch takeoff points on 12" primary irrigation transmission mains at the largest commercial irrigation systems — major golf course and resort irrigation systems, large-acreage agricultural operations, and regional landscape irrigation projects where a 12" primary transmission main must supply an 8" major zone transmission branch or sector supply header carrying a large portion of the primary station output to a major irrigation zone or sector; the 8" branch is the correct specification where the zone or sector flow requirement exceeds the capacity of a 6" branch connection under peak irrigation demand conditions and where the hydraulic design establishes 8" as the required branch pipe size to maintain zone supply pressure and flow rate within the design parameters; the 801-668 provides the manufactured, rated Schedule 80 PVC single-body solution that eliminates field-fabricated tapping assemblies at this primary transmission main major zone branch connection
- Industrial Water & Wastewater Treatment — Primary Process Header High-Volume Branch Connections — Installed at high-volume 8" branch connections on 12" primary process distribution headers in industrial wastewater treatment, water reclamation, and large-scale industrial water management facilities — clarifier influent primary headers supplying major 8" treatment train connections, primary effluent distribution mains branching to high-flow disposal or reuse system connections, aeration system primary air and water distribution headers supplying 8" major zone connections, and primary sludge handling distribution headers serving high-capacity dewatering equipment connections; the 8" branch configuration is specified at primary process header locations where the branch serves a major treatment process section with flow requirements exceeding the 6" branch capacity and approaching the 8" pipe service range; Schedule 80 gray PVC construction handles the chemical service, process fluid contact, and structural loading conditions at 12" primary process header high-volume branch connections in industrial treatment environments
- HVAC & Large Commercial Mechanical Systems — Primary Main Major Branch Supply — Specified at high-volume 8" branch supply connections on 12" primary chilled water distribution mains, condenser water primary trunks, and large-capacity hydronic heating and cooling primary distribution headers in large commercial campus, institutional, and industrial mechanical systems where the 12" primary distribution main must supply an 8" major branch connection to a large building loop, a high-capacity mechanical room supply header, or a major parallel distribution zone carrying a substantial portion of the primary system flow; the 8" branch configuration at HVAC primary distribution level is specified where the branch building loop or zone load requires 8" supply and return connections and a 6" branch would restrict flow below the system's design delivery requirements; the 801-668 provides the manufactured, rated Schedule 80 gray PVC single-body solution for the 12" to 8" major branch connection in large commercial HVAC primary distribution systems
- Aquaculture & Large-Scale Water Management Infrastructure — Used at high-volume 8" branch connections on 12" primary water supply, recirculation, or distribution headers at the largest commercial aquaculture facilities, regional hatchery systems, and large recirculating aquaculture systems (RAS) where system scale has driven primary distribution piping to the 12" size and a major 8" branch connection serves a large parallel filtration train, a high-volume aeration system primary supply, a major water conditioning section, or a large-capacity recirculation loop requiring the 8" branch pipe size to maintain the flow rate and pressure that the parallel system section's design capacity requires; Schedule 80 PVC construction handles the continuous water contact and treatment chemical exposure of commercial aquaculture primary infrastructure, and NSF 61 listing confirms fitness for potable and process water contact at the primary distribution tee junction
The 12" x 12" x 8" Schedule 80 Gray PVC Reducing Tee (801-668, Slip x Slip x Slip) is a large-diameter, heavy-wall specialty tee fitting manufactured to ASTM D2467 in Schedule 80 gray PVC — a reducing tee configuration in which the run connections are 12" and the branch connection is 8", providing a single-body Schedule 80 PVC solution for taking a major 8" branch connection off a 12" primary main without reducing the primary flow path diameter, without field-fabricated saddle taps or custom manifold assemblies, and without transitioning out of Schedule 80 gray PVC construction at the branch takeoff point. In a reducing tee, flow through the 12" run continues uninterrupted through the straight-run ports while the 8" branch connection provides a perpendicular takeoff for major zone supply, high-volume equipment feed, large parallel system connection, or primary sector distribution — the correct large-diameter primary main branch geometry for systems where the 12" primary transmission or distribution main must supply an 8" branch connection that carries a substantial portion of the primary flow to treatment equipment, distribution zones, pump station branches, or parallel process lines while maintaining the full 12" flow path between the tee's run ports.
The 12" x 12" x 8" configuration occupies a distinct position in the large-diameter Schedule 80 PVC reducing tee series that is meaningfully different from both the 12" x 12" x 6" configuration (801-666) and the 12" equal tee (801-120). The 8" branch at 68% of the 12" run diameter is a major branch takeoff — not the relatively modest lateral connection that the 6" branch on the 801-666 represents, and not the equal-diameter three-way split of the 801-120, but a high-volume branch connection serving a system whose branch flow requirements have been engineered at 8" precisely because the zone, sector, or parallel system being supplied demands a branch capacity substantially greater than a 6" connection can provide without unacceptable flow restriction, velocity increase, or pressure loss at the branch entry. In the hydraulic design logic of large-diameter primary PVC systems, the choice between a 6" and an 8" branch off a 12" run reflects a branch flow analysis — the 8" branch is specified where the branch zone or sector carries 40% to 60% of the primary main's full flow capacity, where a 6" branch would create unacceptable pressure loss and velocity at the branch entry under peak flow conditions, and where the hydraulic engineer has determined that the branch pipe must be 8" to maintain the pressure and flow rate the downstream distribution system requires. For commercial irrigation engineers, municipal water system civil engineers, industrial process piping mechanical engineers, and water treatment plant design engineers specifying this branch flow profile on 12" primary mains, the 801-668 is the catalog Schedule 80 PVC fitting that provides the manufactured, rated, specification-compliant single-body solution for the 12" primary to 8" major branch takeoff that cannot be served by the 801-666's 6" branch or the 801-120's equal 12" branch.
Schedule 80 gray PVC construction is the correct and only material specification for this fitting across every application where the 12" x 12" x 8" reducing tee configuration is required. The Schedule 80 wall thickness at both the 12" run and the 8" branch dimensions provides the structural integrity, pressure performance, and mechanical robustness required at a 12" primary main branch connection of this scale and branch size — where internal pressure forces are at the maximum of the commercial PVC fitting line, where the 8" branch entry hydraulic forces subject the tee body to a greater lateral loading than the 6" branch configuration because of the larger branch port area and the higher branch flow volume, and where the fitting must support the combined weight, thermal movement, and operational vibration of connected 12" primary main pipe runs and an 8" branch pipe run simultaneously at the primary manifold location. The gray color provides permanent, inspectable Schedule 80 material class identification at the primary main 8" branch connection — the critical fitting location where material class confirmation is required for system commissioning, AHJ inspection sign-off, and long-term infrastructure asset management documentation. PVC Type 1 Grade 1 construction with cell classification 12454 per ASTM D1784 provides broad chemical resistance across water treatment chemicals, process water service, industrial utility water, and the full range of non-solvent process fluids appropriate for Schedule 80 PVC primary main service. All three socket ends solvent cement directly onto standard IPS Schedule 40 or Schedule 80 PVC pipe of the corresponding nominal sizes — 12" IPS schedule pipe on both run ports and 8" IPS schedule pipe on the branch port. At the 12" socket connections in particular, joint assembly is the most technically demanding in the commercial Schedule 80 PVC fitting line: heavy-body solvent cement rated for large-diameter Schedule 80 PVC is mandatory at all three connections, pre-planned assembly with all components accessible and positioned before cement application begins is essential, full circumferential heavy-body cement coverage across the complete bonding surface of each pipe end and fitting socket must be achieved at both the 12" run sockets and the 8" branch socket, and full cure time compliance before any system pressurization is non-negotiable at this primary main connection where partial cure under system pressure carries the most severe operational and infrastructure consequences in the commercial PVC fitting line.
NSF 61 certification lists this fitting for potable water contact, and NSF 14 covers compliance with applicable plastics piping material standards — making it the correct primary main branch fitting for municipal water treatment and distribution systems, large potable water pump station distribution headers, and large commercial and institutional water supply primary mains where NSF-listed materials are required at every fitting in the primary distribution system. ASTM D2467 governs Schedule 80 PVC socket fittings and defines the manufacturing, dimensional, and pressure performance requirements the 801-668 is produced to. Verify manufacturer pressure rating documentation for the specific fitting configuration before final system specification — at the 12" x 12" x 8" reducing tee configuration, the governing pressure rating is determined by the largest port size (12") and the fitting's tested performance at this large-diameter reducing geometry with an 8" branch, and must be confirmed against the manufacturer's published pressure-temperature rating table for SKU 801-668 before installation in systems at or near the fitting's rated pressure ceiling.
Key Features:
- Schedule 80 gray PVC reducing tee — 12" x 12" run x 8" branch, all socket (slip) ends
- Reducing configuration — major 8" branch takeoff off 12" primary run with full 12" straight-run flow path maintained
- 8" branch at 68% of run diameter — serves high-volume zone supply, major parallel system connections, and sector distribution branches requiring greater capacity than a 6" branch provides
- Manufactured to ASTM D2467 — the governing standard for Schedule 80 PVC socket fittings
- NSF 61 certified for potable water contact; NSF 14 listed
- Solvent cement socket connections compatible with Schedule 40 and Schedule 80 IPS pipe at both run and branch sizes
- Gray color — universal Schedule 80 material class identification at the primary main branch connection
- Single-body fitting solution for 12" primary main to 8" major branch takeoff — eliminates field-fabricated saddle taps and custom manifold assemblies
- Cell classification PVC 12454 per ASTM D1784
- Heavy-body solvent cement required at all three socket connections; full cure time compliance mandatory before pressurization
- Pressure rating: verify against manufacturer pressure-temperature table for SKU 801-668
Specifications:
| Attribute | Value |
|---|---|
| SKU | 801-668 |
| Fitting Type | Reducing Tee |
| Run Size | 12" x 12" |
| Branch Size | 8" |
| End Connections | Slip x Slip x Slip (All Socket) |
| Connection Method | Solvent Cement (IPS) |
| Compatible Pipe — Run | 12" IPS Schedule 40 or Schedule 80 PVC |
| Compatible Pipe — Branch | 8" IPS Schedule 40 or Schedule 80 PVC |
| Schedule | Schedule 80 |
| Material | PVC (Polyvinyl Chloride) Type 1, Grade 1 |
| Cell Classification | 12454 per ASTM D1784 |
| Color | Gray |
| Manufacturing Standard | ASTM D2467 |
| Potable Water Certification | NSF/ANSI 61 |
| Plastics Standard Certification | NSF 14 |
| Max Service Temperature | 140°F (60°C) |
| Pressure Rating | Verify with manufacturer pressure-temperature rating table for SKU 801-668 |
Industries & Applications:
- Municipal Water Distribution — Primary Transmission Main Major Branch Connections — The 12" x 12" x 8" reducing tee is specified at high-volume 8" branch takeoff points on 12" municipal water transmission and primary distribution mains — connections supplying 8" primary zone transmission laterals, major pressure zone supply headers, large-diameter fire flow supply mains, and high-volume sector distribution branches where the branch flow requirement at the 12" primary main junction demands a full 8" port that the 801-666's 6" branch cannot serve without unacceptable pressure loss and velocity at the branch entry under peak demand conditions; at municipal scale, every branch connection fitting on a 12" primary transmission main is a formally specified, permitted, and inspected infrastructure component — the 801-668 provides the manufactured, rated, NSF-listed, ASTM D2467-compliant single-body Schedule 80 PVC solution for the high-volume 8" branch connection requirement at primary transmission main junction points in large municipal PVC water distribution system construction where the branch flow analysis has established 8" as the correct branch pipe size
- Water Treatment Plant — Primary Header Major Branch Connections — Installed at high-volume 8" branch connection points on 12" primary distribution headers in municipal and industrial water treatment plants — clearwell supply and distribution primary trunks supplying major 8" zone distribution headers, filter influent and effluent primary headers branching to large parallel filter train supply connections, backwash primary supply mains connecting to 8" backwash equipment headers, and plant service water primary headers supplying 8" major equipment supply branches; the 8" branch configuration is specified at water treatment plant primary header locations where the branch serves a major equipment train or distribution zone with flow requirements that exceed the capacity of a 6" branch connection and approach the capacity of the 8" service pipe size; NSF 61 listing makes this fitting appropriate for every potable water treatment primary distribution major branch connection, and Schedule 80 gray PVC construction satisfies the material class and pressure performance requirements at these large-diameter primary header branch connection locations
- Pump Station — Primary Header to Major Branch Supply Connections — Used at 8" major branch supply connections off 12" primary pump station headers in large pump stations, booster pump stations, municipal well field pump stations, and water storage facility pump rooms where the 12" primary pump discharge or suction header must supply an 8" branch connection to a major pump train, a high-volume pressure zone supply connection, a parallel pump station primary header, or a large-capacity zone isolation valve assembly; the 8" branch at pump station primary header level is the correct specification where the branch serves a pump unit or zone with output or supply requirements that a 6" branch connection would restrict under full pump station operating conditions; at primary pump station header branch connections of this scale, the 801-668 is the single-body Schedule 80 PVC fitting that provides a manufactured, rated, code-compliant 8" branch connection without field-fabricated configurations that introduce additional leak points and material class documentation complications at the most hydraulically active location in the pump station piping
- Industrial Process Piping — Primary Header High-Volume Branch Takeoffs — Used at high-volume 8" branch takeoff points on 12" process water primary headers, cooling water primary distribution trunks, plant utility water primary mains, and large-volume industrial process fluid primary distribution headers in manufacturing plants, chemical processing facilities, petrochemical support facilities, and heavy industrial environments where the 12" primary process header must supply an 8" branch to a major equipment section, a high-flow process unit, a large parallel distribution system, or a primary sector supply header carrying a substantial portion of the primary header flow; the 8" branch configuration is specified at industrial primary header locations where the branch flow analysis establishes 8" as the correct branch pipe size — where the downstream process section demand exceeds what a 6" branch can supply without pressure and velocity penalties and where a full equal 12" branch is more than the branch section requires; Schedule 80 gray PVC construction provides the chemical resistance, structural wall thickness, and material class documentation required at large-diameter primary header branch connections in industrial process piping systems
- Large Commercial & Agricultural Irrigation — Primary Trunk Major Zone Branch Connections — Specified at high-volume 8" branch takeoff points on 12" primary irrigation transmission mains at the largest commercial irrigation systems — major golf course and resort irrigation systems, large-acreage agricultural operations, and regional landscape irrigation projects where a 12" primary transmission main must supply an 8" major zone transmission branch or sector supply header carrying a large portion of the primary station output to a major irrigation zone or sector; the 8" branch is the correct specification where the zone or sector flow requirement exceeds the capacity of a 6" branch connection under peak irrigation demand conditions and where the hydraulic design establishes 8" as the required branch pipe size to maintain zone supply pressure and flow rate within the design parameters; the 801-668 provides the manufactured, rated Schedule 80 PVC single-body solution that eliminates field-fabricated tapping assemblies at this primary transmission main major zone branch connection
- Industrial Water & Wastewater Treatment — Primary Process Header High-Volume Branch Connections — Installed at high-volume 8" branch connections on 12" primary process distribution headers in industrial wastewater treatment, water reclamation, and large-scale industrial water management facilities — clarifier influent primary headers supplying major 8" treatment train connections, primary effluent distribution mains branching to high-flow disposal or reuse system connections, aeration system primary air and water distribution headers supplying 8" major zone connections, and primary sludge handling distribution headers serving high-capacity dewatering equipment connections; the 8" branch configuration is specified at primary process header locations where the branch serves a major treatment process section with flow requirements exceeding the 6" branch capacity and approaching the 8" pipe service range; Schedule 80 gray PVC construction handles the chemical service, process fluid contact, and structural loading conditions at 12" primary process header high-volume branch connections in industrial treatment environments
- HVAC & Large Commercial Mechanical Systems — Primary Main Major Branch Supply — Specified at high-volume 8" branch supply connections on 12" primary chilled water distribution mains, condenser water primary trunks, and large-capacity hydronic heating and cooling primary distribution headers in large commercial campus, institutional, and industrial mechanical systems where the 12" primary distribution main must supply an 8" major branch connection to a large building loop, a high-capacity mechanical room supply header, or a major parallel distribution zone carrying a substantial portion of the primary system flow; the 8" branch configuration at HVAC primary distribution level is specified where the branch building loop or zone load requires 8" supply and return connections and a 6" branch would restrict flow below the system's design delivery requirements; the 801-668 provides the manufactured, rated Schedule 80 gray PVC single-body solution for the 12" to 8" major branch connection in large commercial HVAC primary distribution systems
- Aquaculture & Large-Scale Water Management Infrastructure — Used at high-volume 8" branch connections on 12" primary water supply, recirculation, or distribution headers at the largest commercial aquaculture facilities, regional hatchery systems, and large recirculating aquaculture systems (RAS) where system scale has driven primary distribution piping to the 12" size and a major 8" branch connection serves a large parallel filtration train, a high-volume aeration system primary supply, a major water conditioning section, or a large-capacity recirculation loop requiring the 8" branch pipe size to maintain the flow rate and pressure that the parallel system section's design capacity requires; Schedule 80 PVC construction handles the continuous water contact and treatment chemical exposure of commercial aquaculture primary infrastructure, and NSF 61 listing confirms fitness for potable and process water contact at the primary distribution tee junction
- Part #:
- 801-668
- Product Family:
- Sch 80 PVC
- Carton Qty:
- 1
- Pallet Qty:
- 3
- Size:
- 12"