Tee, Slip x Slip x FPT PVC Schedule 80 1-1/2" (802-015)
The 802-015 is a 1-1/2" PVC Schedule 80 tee in a slip x slip x FPT (Female Pipe Thread) configuration, providing a full-bore 90-degree branch connection with 1-1/2" slip inlets on both run ends and a matching 1-1/2" FPT branch outlet. All three ports are the same size, making this a full-size tee — not a reducing fitting — and the FPT branch is the sole distinction from the all-slip 801-series equivalent at the same size.
That single distinction is the defining value of the 802-015: the solvent-welded run ports create a permanent, leak-free mainline, while the full-size 1-1/2" FPT branch remains independently serviceable — accepting any standard 1-1/2" MPT fitting that can be installed, removed, or replaced without disturbing the cemented run. This makes the 802-015 the preferred tee wherever the branch connection must carry full mainline flow capacity and also needs to remain accessible for maintenance, isolation, reconfiguration, or seasonal service.
Common branch applications at the full 1-1/2" FPT port include full-bore ball valves for branch isolation, threaded unions for equipment disconnects, nipple-and-valve assemblies for pump or filter connections, and capped outlets reserved for future branch expansion. In each case, the threaded branch provides a level of operational flexibility that a solvent-welded branch cannot offer once cemented.
Schedule 80's thicker wall construction delivers higher pressure ratings and stronger resistance to mechanical stress and chemical exposure than Schedule 40, making this tee appropriate for demanding industrial, chemical, and process environments. The gray color is the standard Schedule 80 identifier, providing clear visual differentiation from white Schedule 40 components in mixed systems.
Installation on the run ports follows standard solvent cement practice — clean, prime, and cement per ASTM D2564 procedures. For the 1-1/2" FPT branch, apply PTFE thread tape or a compatible PVC-rated thread sealant to the male threads of the mating fitting before assembly. Avoid petroleum-based pipe dopes, which can degrade PVC over time. Thread by hand first, then snug with a strap wrench — do not over-tighten, as excessive torque risks cracking PVC female threads at this port size.
Specifications:
| Attribute | Detail |
|---|---|
| Part Number | 802-015 |
| Material | PVC (Polyvinyl Chloride) |
| Schedule | Schedule 80 |
| Color | Gray |
| Fitting Type | Tee |
| End Connections | Slip x Slip x FPT |
| Run Size | 1-1/2" |
| Branch Size | 1-1/2" |
| Run Installation Method | Solvent Cement Weld |
| Branch Installation Method | Threaded (PTFE Tape or Compatible Thread Sealant) |
| Pressure Rating | Per ASTM D2464 / manufacturer Schedule 80 ratings (derate at elevated temperatures) |
| Temperature Range | Up to 140°F (60°C) for pressure service |
| Standard | ASTM D2464 |
| Suitable Fluids | Water, dilute acids, bases, and a broad range of chemicals compatible with PVC |
Industries & Applications:
The 802-015 is well-suited for Schedule 80 systems requiring a full-bore, serviceable threaded branch off a permanent 1-1/2" solvent-weld mainline:
- Industrial Processing — Full-bore threaded branch connections for isolation valves, bypass circuits, and equipment feed takeoffs in 1-1/2" process piping headers where the branch must carry mainline flow capacity and remain independently serviceable
- Chemical Handling — Full-size threaded branch outlets in acid, alkali, and reagent distribution systems — particularly at valve-controlled secondary circuits, tank fill connections, and transfer lines where the branch fitting must be removed or replaced periodically without cutting the mainline
- Water & Wastewater Treatment — Full-bore branch connections at pump stations, chemical dosing headers, and distribution manifolds in treatment plant piping where a threaded branch valve or instrument assembly must be serviced independently of the permanent mainline run
- Irrigation & Agriculture — Full-size threaded branch takeoffs in pressurized irrigation mainlines at zone valve assemblies, filter station connections, and distribution headers where seasonal removal or reconfiguration of the branch fitting is required
- Commercial & Industrial Plumbing — Full-bore threaded branch connections in cold water supply, equipment feed lines, and mechanical room piping where a serviceable branch valve, union, or equipment connection must be accessible at a permanent solvent-weld tee point
- Aquaculture & Aquatics — Full-size threaded branch connections at filter headers, pump bypass takeoffs, and major recirculating system junctions where branch serviceability is required alongside a permanent mainline installation
- Pool & Spa — Full-bore branch connections at commercial pool mechanical equipment pads, main circulation headers, and chemical feed distribution points where threaded branch valves or equipment connections must remain serviceable
- HVAC & Cooling Systems — Full-bore threaded branch takeoffs in chilled water and process cooling distribution circuits where a serviceable branch valve, isolation assembly, or equipment connection is required off a permanent 1-1/2" mainline
The 802-015 is a 1-1/2" PVC Schedule 80 tee in a slip x slip x FPT (Female Pipe Thread) configuration, providing a full-bore 90-degree branch connection with 1-1/2" slip inlets on both run ends and a matching 1-1/2" FPT branch outlet. All three ports are the same size, making this a full-size tee — not a reducing fitting — and the FPT branch is the sole distinction from the all-slip 801-series equivalent at the same size.
That single distinction is the defining value of the 802-015: the solvent-welded run ports create a permanent, leak-free mainline, while the full-size 1-1/2" FPT branch remains independently serviceable — accepting any standard 1-1/2" MPT fitting that can be installed, removed, or replaced without disturbing the cemented run. This makes the 802-015 the preferred tee wherever the branch connection must carry full mainline flow capacity and also needs to remain accessible for maintenance, isolation, reconfiguration, or seasonal service.
Common branch applications at the full 1-1/2" FPT port include full-bore ball valves for branch isolation, threaded unions for equipment disconnects, nipple-and-valve assemblies for pump or filter connections, and capped outlets reserved for future branch expansion. In each case, the threaded branch provides a level of operational flexibility that a solvent-welded branch cannot offer once cemented.
Schedule 80's thicker wall construction delivers higher pressure ratings and stronger resistance to mechanical stress and chemical exposure than Schedule 40, making this tee appropriate for demanding industrial, chemical, and process environments. The gray color is the standard Schedule 80 identifier, providing clear visual differentiation from white Schedule 40 components in mixed systems.
Installation on the run ports follows standard solvent cement practice — clean, prime, and cement per ASTM D2564 procedures. For the 1-1/2" FPT branch, apply PTFE thread tape or a compatible PVC-rated thread sealant to the male threads of the mating fitting before assembly. Avoid petroleum-based pipe dopes, which can degrade PVC over time. Thread by hand first, then snug with a strap wrench — do not over-tighten, as excessive torque risks cracking PVC female threads at this port size.
Specifications:
| Attribute | Detail |
|---|---|
| Part Number | 802-015 |
| Material | PVC (Polyvinyl Chloride) |
| Schedule | Schedule 80 |
| Color | Gray |
| Fitting Type | Tee |
| End Connections | Slip x Slip x FPT |
| Run Size | 1-1/2" |
| Branch Size | 1-1/2" |
| Run Installation Method | Solvent Cement Weld |
| Branch Installation Method | Threaded (PTFE Tape or Compatible Thread Sealant) |
| Pressure Rating | Per ASTM D2464 / manufacturer Schedule 80 ratings (derate at elevated temperatures) |
| Temperature Range | Up to 140°F (60°C) for pressure service |
| Standard | ASTM D2464 |
| Suitable Fluids | Water, dilute acids, bases, and a broad range of chemicals compatible with PVC |
Industries & Applications:
The 802-015 is well-suited for Schedule 80 systems requiring a full-bore, serviceable threaded branch off a permanent 1-1/2" solvent-weld mainline:
- Industrial Processing — Full-bore threaded branch connections for isolation valves, bypass circuits, and equipment feed takeoffs in 1-1/2" process piping headers where the branch must carry mainline flow capacity and remain independently serviceable
- Chemical Handling — Full-size threaded branch outlets in acid, alkali, and reagent distribution systems — particularly at valve-controlled secondary circuits, tank fill connections, and transfer lines where the branch fitting must be removed or replaced periodically without cutting the mainline
- Water & Wastewater Treatment — Full-bore branch connections at pump stations, chemical dosing headers, and distribution manifolds in treatment plant piping where a threaded branch valve or instrument assembly must be serviced independently of the permanent mainline run
- Irrigation & Agriculture — Full-size threaded branch takeoffs in pressurized irrigation mainlines at zone valve assemblies, filter station connections, and distribution headers where seasonal removal or reconfiguration of the branch fitting is required
- Commercial & Industrial Plumbing — Full-bore threaded branch connections in cold water supply, equipment feed lines, and mechanical room piping where a serviceable branch valve, union, or equipment connection must be accessible at a permanent solvent-weld tee point
- Aquaculture & Aquatics — Full-size threaded branch connections at filter headers, pump bypass takeoffs, and major recirculating system junctions where branch serviceability is required alongside a permanent mainline installation
- Pool & Spa — Full-bore branch connections at commercial pool mechanical equipment pads, main circulation headers, and chemical feed distribution points where threaded branch valves or equipment connections must remain serviceable
- HVAC & Cooling Systems — Full-bore threaded branch takeoffs in chilled water and process cooling distribution circuits where a serviceable branch valve, isolation assembly, or equipment connection is required off a permanent 1-1/2" mainline
- Part #:
- 802-015
- Product Family:
- Sch 80 PVC
- Carton Qty:
- 5
- Pallet Qty:
- 960
- Size:
- 1-1/2"