Tee, Slip x Slip x FPT PVC Schedule 80 2" x 1" (802-249)
The 802-249 is a PVC Schedule 80 reducing tee with a 2" slip (socket) run and a 1" female pipe thread (FPT) branch outlet. The two 2" run ports accept solvent cement welding per ASTM D2564 for a permanent, pressure-rated inline connection, while the 1" FPT branch provides a threaded takeoff point compatible with any standard 1" NPT male-threaded fitting, valve, gauge, or instrument — no solvent welding required at the branch.
Manufactured from rigid, dark gray PVC compound conforming to ASTM D1784 cell classification requirements, Schedule 80 wall thickness is substantially greater than Schedule 40, delivering higher pressure ratings at equivalent pipe sizes and added durability in demanding service environments. This makes the 802-249 the appropriate choice for high-pressure distribution systems, chemical process piping, and industrial applications where Schedule 40 pressure ratings are insufficient.
The combination of solvent weld run ends and a threaded branch is a practical configuration for systems that require a fixed, permanent mainline with a serviceable or removable branch connection — allowing valves, gauges, sensors, or instruments to be installed, inspected, or replaced at the branch port without disturbing the solvent-welded mainline. This hybrid end configuration is commonly specified in chemical processing, industrial water treatment, and high-pressure irrigation systems.
Specifications:
| Attribute | Detail |
|---|---|
| Part Number | 802-249 |
| Material | PVC (Polyvinyl Chloride) |
| Schedule / Class | Schedule 80 |
| Fitting Type | Reducing Tee |
| Run End Connection | Slip (Socket) — Solvent Cement Weld |
| Branch End Connection | FPT (Female Pipe Thread / NPT) |
| Run Size | 2" |
| Branch Size | 1" |
| Connection Method | Solvent Cement Weld (run) / Threaded NPT (branch) |
| Pressure Rating | Rated per ASTM D2467 (temperature and size dependent) |
| Temperature Range | Up to 140°F (60°C) for pressure service |
| Color | Dark Gray |
| Standards | ASTM D2467 (socket), ASTM D2464 (threaded), ASTM D1784 |
| Listing | NSF/ANSI 61 (potable water contact) |
Industries & Applications:
- Industrial Process Piping — High-pressure distribution systems requiring a serviceable threaded branch for valves, gauges, or instrumentation off a permanent solvent-welded mainline
- Chemical Processing — Corrosion-resistant piping systems handling acids, caustics, and aggressive fluids where Schedule 80 wall thickness provides added safety margin
- Municipal Water & Wastewater — Pump station and treatment facility piping where branch connections must accommodate removable instrumentation or pressure monitoring ports
- Irrigation & Agriculture — High-pressure mainline systems with threaded branch takeoffs for zone valves, pressure regulators, or flow control fittings
- HVAC & Mechanical — Chilled water and process cooling systems requiring robust fittings with accessible branch connections for gauges or balancing valves
- Aquaculture & Water Treatment — Recirculating system manifolds where branch ports must accommodate removable or adjustable flow control components
The 802-249 is a PVC Schedule 80 reducing tee with a 2" slip (socket) run and a 1" female pipe thread (FPT) branch outlet. The two 2" run ports accept solvent cement welding per ASTM D2564 for a permanent, pressure-rated inline connection, while the 1" FPT branch provides a threaded takeoff point compatible with any standard 1" NPT male-threaded fitting, valve, gauge, or instrument — no solvent welding required at the branch.
Manufactured from rigid, dark gray PVC compound conforming to ASTM D1784 cell classification requirements, Schedule 80 wall thickness is substantially greater than Schedule 40, delivering higher pressure ratings at equivalent pipe sizes and added durability in demanding service environments. This makes the 802-249 the appropriate choice for high-pressure distribution systems, chemical process piping, and industrial applications where Schedule 40 pressure ratings are insufficient.
The combination of solvent weld run ends and a threaded branch is a practical configuration for systems that require a fixed, permanent mainline with a serviceable or removable branch connection — allowing valves, gauges, sensors, or instruments to be installed, inspected, or replaced at the branch port without disturbing the solvent-welded mainline. This hybrid end configuration is commonly specified in chemical processing, industrial water treatment, and high-pressure irrigation systems.
Specifications:
| Attribute | Detail |
|---|---|
| Part Number | 802-249 |
| Material | PVC (Polyvinyl Chloride) |
| Schedule / Class | Schedule 80 |
| Fitting Type | Reducing Tee |
| Run End Connection | Slip (Socket) — Solvent Cement Weld |
| Branch End Connection | FPT (Female Pipe Thread / NPT) |
| Run Size | 2" |
| Branch Size | 1" |
| Connection Method | Solvent Cement Weld (run) / Threaded NPT (branch) |
| Pressure Rating | Rated per ASTM D2467 (temperature and size dependent) |
| Temperature Range | Up to 140°F (60°C) for pressure service |
| Color | Dark Gray |
| Standards | ASTM D2467 (socket), ASTM D2464 (threaded), ASTM D1784 |
| Listing | NSF/ANSI 61 (potable water contact) |
Industries & Applications:
- Industrial Process Piping — High-pressure distribution systems requiring a serviceable threaded branch for valves, gauges, or instrumentation off a permanent solvent-welded mainline
- Chemical Processing — Corrosion-resistant piping systems handling acids, caustics, and aggressive fluids where Schedule 80 wall thickness provides added safety margin
- Municipal Water & Wastewater — Pump station and treatment facility piping where branch connections must accommodate removable instrumentation or pressure monitoring ports
- Irrigation & Agriculture — High-pressure mainline systems with threaded branch takeoffs for zone valves, pressure regulators, or flow control fittings
- HVAC & Mechanical — Chilled water and process cooling systems requiring robust fittings with accessible branch connections for gauges or balancing valves
- Aquaculture & Water Treatment — Recirculating system manifolds where branch ports must accommodate removable or adjustable flow control components
- Part #:
- 802-249
- Product Family:
- Sch 80 PVC
- Carton Qty:
- 10
- Pallet Qty:
- 800
- Size:
- 2"