Tee, Slip x Slip x Slip PVC Schedule 80 12" (801-120)

SKU:
801-120
|
UPC:
054211168189
Availability:
Typically ships within 24 hrs
$1,282.34

The 12" Schedule 80 Gray PVC Tee (801-120, Slip x Slip x Slip) is a large-diameter, heavy-wall equal tee fitting manufactured to ASTM D2467 in Schedule 80 gray PVC — all three ports at 12", providing a single-body Schedule 80 PVC solution for equal branch takeoffs, equal flow splits, and equal three-way distribution connections on 12" primary transmission and distribution mains where the branch flow requirement is equal in diameter to the primary run and the fitting must be a rated, manufactured, NSF-listed, ASTM D2467-compliant Schedule 80 gray PVC component at the most hydraulically significant branch connection point in the large-diameter piping system. In an equal tee, the branch is the same diameter as the run — meaning a 12" primary main continues through the straight-run ports while a full 12" branch connection is provided perpendicular to the run, accommodating the full primary pipe diameter at the branch takeoff point. The 801-120 is the correct fitting where that branch connection requires a full 12" port — where the branch flow requirement is equal to or approaches the full flow capacity of the 12" primary main, where a reducing tee with a smaller branch would create unacceptable flow restriction or velocity increase at the branch entry, or where the system design requires a full 12" branch port for equal-diameter zone supply, parallel system connection, primary trunk split, or manifold configuration that demands the same pipe diameter throughout the three-way connection.

The 12" equal tee is one of the most consequential single fittings in the large-diameter Schedule 80 PVC line. Unlike reducing tees and bullhead tees where the size differential between run and branch introduces its own hydraulic management logic, the equal tee at 12" places the full primary flow capacity of the largest standard commercial Schedule 80 PVC socket fitting at a three-way junction — where a 12" primary main divides and distributes into a 12" straight-run continuation and a 12" perpendicular branch simultaneously, or where two 12" flows combine at a single fitting body. The hydraulic conditions at the equal tee junction on a 12" primary main are among the most demanding in the commercial PVC fitting line: the branch entry velocity, the directional change of flow from run to branch, and the pressure forces acting on the tee body at the three-way junction under full 12" primary main flow conditions all impose structural and pressure loading on the fitting that make Schedule 80 wall thickness and ASTM D2467 manufacturing compliance the correct and only specification at this service size and configuration. For commercial irrigation engineers, municipal water system civil engineers, industrial process piping mechanical engineers, and water treatment plant design engineers specifying 12" primary main branch connections where a full 12" port is required at the branch, the 801-120 is the catalog Schedule 80 PVC fitting that provides the manufactured, rated, specification-compliant single-body solution without field-fabricated tee assemblies, saddle connections, or custom fitting configurations that introduce additional joint count, potential leak points, and material class documentation complications at the primary main branch connection.

Schedule 80 gray PVC construction is the correct and only material specification for this fitting at the 12" equal tee configuration. The Schedule 80 wall thickness at the 12" port dimensions — applied uniformly across the run body, the branch body, and the full tee junction — provides the structural integrity, pressure performance, and mechanical robustness required at a 12" three-way primary main junction where internal pressure forces, hydraulic branch entry loads, and the mechanical weight and thermal movement of three connected 12" primary pipe runs impose the maximum combined structural loading of any fitting configuration in the commercial Schedule 80 PVC socket fitting line. The gray color provides permanent, inspectable Schedule 80 material class identification at the primary main tee junction — the most structurally and hydraulically active fitting location in the 12" system, and the location where material class confirmation carries the highest consequence for system commissioning documentation, AHJ inspection sign-off, and long-term infrastructure asset management. PVC Type 1 Grade 1 construction with cell classification 12454 per ASTM D1784 provides broad chemical resistance across water treatment chemicals, process water service, industrial utility water, and the full range of non-solvent process fluids appropriate for Schedule 80 PVC primary main service. All three socket ends solvent cement directly onto standard 12" IPS Schedule 40 or Schedule 80 PVC pipe using heavy-body solvent cement appropriate for the large bonding surface areas of each 12" socket. At the 12" socket connections, joint assembly is the most technically demanding in the commercial Schedule 80 PVC fitting line: heavy-body solvent cement rated for large-diameter Schedule 80 PVC is mandatory at all three connections, pre-planned assembly with all three pipe connections accessible and positioned before cement application begins is essential to manage working time across three large-diameter socket joints on a single fitting body, full circumferential heavy-body cement coverage across the complete bonding surface of each 12" pipe end and fitting socket must be achieved, and full cure time compliance before any system pressurization is non-negotiable at this primary main tee junction where partial cure under system pressure carries the most severe operational and infrastructure consequences of any equal tee configuration in the commercial PVC fitting line.

NSF 61 certification lists this fitting for potable water contact, and NSF 14 covers compliance with applicable plastics piping material standards — making it the correct primary main tee fitting for municipal water treatment and distribution systems, large potable water pump station distribution headers, and large commercial and institutional water supply primary mains where NSF-listed materials are required at every fitting in the primary distribution system. ASTM D2467 governs Schedule 80 PVC socket fittings and defines the manufacturing, dimensional, and pressure performance requirements the 801-120 is produced to. Verify manufacturer pressure rating documentation for the specific fitting configuration before final system specification — at the 12" equal tee configuration, the governing pressure rating is determined by the 12" port size and the fitting's tested performance at the equal tee geometry under the combined hydraulic conditions of three full-diameter 12" port connections, and must be confirmed against the manufacturer's published pressure-temperature rating table for SKU 801-120 before installation in systems at or near the fitting's rated pressure ceiling.

Key Features:

  • Schedule 80 gray PVC equal tee — 12" x 12" x 12", all socket (slip) ends
  • Equal configuration — full 12" branch port equal in diameter to the 12" primary run
  • Manufactured to ASTM D2467 — the governing standard for Schedule 80 PVC socket fittings
  • NSF 61 certified for potable water contact; NSF 14 listed
  • Solvent cement socket connections compatible with Schedule 40 and Schedule 80 IPS 12" pipe at all three ports
  • Gray color — universal Schedule 80 material class identification at the primary main tee junction
  • Single-body fitting for 12" equal branch takeoffs, equal flow splits, and three-way primary main distribution connections
  • Cell classification PVC 12454 per ASTM D1784
  • Heavy-body solvent cement required at all three 12" socket connections; full cure time compliance mandatory before pressurization
  • Pressure rating: verify against manufacturer pressure-temperature table for SKU 801-120

Specifications:

Attribute Value
SKU 801-120
Fitting Type Equal Tee
Run Size 12" x 12"
Branch Size 12"
End Connections Slip x Slip x Slip (All Socket)
Connection Method Solvent Cement (IPS)
Compatible Pipe — All Ports 12" IPS Schedule 40 or Schedule 80 PVC
Schedule Schedule 80
Material PVC (Polyvinyl Chloride) Type 1, Grade 1
Cell Classification 12454 per ASTM D1784
Color Gray
Manufacturing Standard ASTM D2467
Potable Water Certification NSF/ANSI 61
Plastics Standard Certification NSF 14
Max Service Temperature 140°F (60°C)
Pressure Rating Verify with manufacturer pressure-temperature rating table for SKU 801-120

Industries & Applications:

  • Municipal Water Distribution — Primary Transmission Main Equal Branch Connections — The 12" equal tee is specified at full 12" branch takeoff points on 12" municipal water transmission and primary distribution mains — connections supplying 12" zone transmission laterals, parallel distribution trunk branches, primary pressure zone supply headers, and large-diameter fire flow supply branches where the branch flow requirement at the 12" primary main junction demands a full 12" port that a reducing tee cannot provide without branch flow restriction; at municipal scale, the 12" primary transmission main is capital water supply infrastructure designed by licensed civil engineers and inspected by water system AHJs, and every branch connection fitting is a formally specified, permitted, and inspected infrastructure component — the 801-120 provides the manufactured, rated, NSF-listed, ASTM D2467-compliant single-body Schedule 80 PVC solution for the full 12" branch connection requirement at primary transmission main junction points in large municipal PVC water distribution system construction
  • Water Treatment Plant — Primary Header Equal Branch Connections — Installed at full 12" branch connection points on 12" primary distribution headers in municipal and industrial water treatment plants — clearwell supply and distribution primary trunks, filter influent and effluent primary headers, backwash primary supply mains, and plant service water primary headers where a full 12" branch connection serves a parallel filter train, a redundant supply path, a parallel treatment equipment supply, or an equal-capacity zone distribution branch; the equal tee configuration is specified where the branch flow requirement at the 12" primary header equals the primary run capacity and a reducing tee with a smaller branch port would create unacceptable flow restriction or velocity imbalance across the tee junction; NSF 61 listing makes this fitting appropriate for every potable water treatment primary distribution equal branch connection, and Schedule 80 gray PVC construction satisfies the material class requirements of water treatment plant primary distribution piping specifications at the largest service sizes
  • Pump Station — Primary Header Three-Way Connections and Flow Splits — Used at three-way connection points in large pump station primary headers where a 12" primary pump discharge or suction header must split equally into two parallel 12" distribution branches, where two 12" pump discharge connections must combine at a three-way primary header junction, or where a 12" primary suction or discharge header must supply a full 12" branch to a parallel pump train, zone isolation valve assembly, or primary check valve bypass connection; the equal tee geometry at 12" provides the full-diameter three-way junction capability for pump station header configurations where the branch flow volume, the primary suction or discharge hydraulic conditions, or the equal-distribution manifold design requires a full 12" branch port throughout the three-way connection; at primary pump station header connections of this scale, the 801-120 is the single-body manufactured Schedule 80 PVC solution that eliminates field-fabricated three-way assemblies and provides a rated, code-compliant primary manifold fitting
  • Industrial Process Piping — Primary Header Equal Branch Takeoffs — Used at full 12" branch connection points on 12" process water primary headers, cooling water primary distribution trunks, plant utility water primary mains, and large-volume industrial process fluid primary distribution headers in manufacturing plants, chemical processing facilities, petrochemical support facilities, and heavy industrial environments where the 12" primary process header must supply a full 12" branch to a major equipment train, a parallel process unit, a secondary distribution trunk, or an equal-capacity redundant supply path; Schedule 80 gray PVC construction provides the chemical resistance, structural wall thickness, and material class identification required at large-diameter primary header equal branch connections in industrial process piping systems where Schedule 80 is the system-wide material standard and every primary manifold fitting must carry full engineering specification documentation
  • Large Commercial & Agricultural Irrigation — Primary Trunk Equal Branch Connections — Specified at full 12" branch takeoff points on 12" primary irrigation transmission mains at the largest commercial irrigation systems — major golf course and resort irrigation systems, large-acreage corporate agricultural operations, municipal parks and sports complex irrigation systems, and regional landscape irrigation projects where a 12" primary transmission main must supply a full 12" zone transmission branch, a parallel sector supply header, or a secondary distribution trunk of equal capacity to the primary run; the equal tee configuration is the correct specification where the branch zone or sector flow requirement at the 12" primary main equals the primary run capacity and the hydraulic design requires a full 12" branch port to maintain the zone supply pressure and flow rate that the irrigation system design specifies; the 801-120 provides the manufactured, rated Schedule 80 PVC single-body solution for this primary transmission main equal branch configuration
  • Industrial Water & Wastewater Treatment — Primary Process Header Three-Way Junctions — Installed at equal three-way connection points on 12" primary process distribution headers in industrial wastewater treatment, water reclamation, and large-scale industrial water management facilities — clarifier influent primary headers splitting into parallel treatment trains, primary effluent distribution mains branching to parallel disposal or reuse systems, and primary sludge handling distribution headers serving parallel dewatering equipment trains where a full 12" three-way junction is required to maintain equal flow distribution across both branches of the primary process header; Schedule 80 gray PVC construction handles the chemical service, process fluid contact, and structural loading conditions at 12" primary process header equal three-way junctions in industrial treatment environments, and the single-body 801-120 configuration eliminates the fabricated fitting assemblies that add joint count and inspection complications at the primary process header level
  • HVAC & Large Commercial Mechanical Systems — Primary Main Three-Way Distribution — Specified at full 12" three-way junction points on 12" primary chilled water distribution mains, condenser water primary trunks, and large-capacity hydronic heating and cooling primary distribution headers in large commercial campus, institutional, and industrial mechanical systems where the 12" primary distribution main must split into a 12" straight-run continuation and a full 12" branch connection to supply parallel building loops, equal-capacity mechanical room supply headers, or redundant distribution paths of equal pipe diameter to the primary main; at the 12" primary distribution level in large commercial HVAC systems, three-way junction fittings are primary infrastructure components formally specified by licensed mechanical engineers, and the 801-120 provides the manufactured, rated, Schedule 80 gray PVC single-body solution for the 12" equal three-way distribution requirement in large commercial and institutional HVAC primary distribution systems where Schedule 80 PVC is the system material standard
  • Aquaculture, Large Recirculating Systems & Water Management Infrastructure — Used at full 12" three-way distribution and collection junction points in the largest commercial aquaculture facilities, regional hatchery systems, and large recirculating aquaculture systems (RAS) where primary water supply, recirculation, or distribution headers at the 12" size must branch equally at a three-way junction to supply parallel filtration trains, equal-capacity recirculation loops, or parallel water conditioning and treatment systems of equal flow capacity to the primary trunk; the 12" equal tee configuration is specified where the branch connection requirement equals the primary header diameter and a reducing tee would restrict the branch flow below the parallel system's design capacity; Schedule 80 PVC construction handles the continuous water contact and water treatment chemical exposure of primary aquaculture infrastructure, and NSF 61 listing confirms fitness for potable and process water contact at the primary distribution tee junction
(No reviews yet)
Width:
14.25 (in)
Height:
19.88 (in)
Depth:
25.88 (in)
Condition:
New
Current Stock:
Adding to cart… The item has been added

The 12" Schedule 80 Gray PVC Tee (801-120, Slip x Slip x Slip) is a large-diameter, heavy-wall equal tee fitting manufactured to ASTM D2467 in Schedule 80 gray PVC — all three ports at 12", providing a single-body Schedule 80 PVC solution for equal branch takeoffs, equal flow splits, and equal three-way distribution connections on 12" primary transmission and distribution mains where the branch flow requirement is equal in diameter to the primary run and the fitting must be a rated, manufactured, NSF-listed, ASTM D2467-compliant Schedule 80 gray PVC component at the most hydraulically significant branch connection point in the large-diameter piping system. In an equal tee, the branch is the same diameter as the run — meaning a 12" primary main continues through the straight-run ports while a full 12" branch connection is provided perpendicular to the run, accommodating the full primary pipe diameter at the branch takeoff point. The 801-120 is the correct fitting where that branch connection requires a full 12" port — where the branch flow requirement is equal to or approaches the full flow capacity of the 12" primary main, where a reducing tee with a smaller branch would create unacceptable flow restriction or velocity increase at the branch entry, or where the system design requires a full 12" branch port for equal-diameter zone supply, parallel system connection, primary trunk split, or manifold configuration that demands the same pipe diameter throughout the three-way connection.

The 12" equal tee is one of the most consequential single fittings in the large-diameter Schedule 80 PVC line. Unlike reducing tees and bullhead tees where the size differential between run and branch introduces its own hydraulic management logic, the equal tee at 12" places the full primary flow capacity of the largest standard commercial Schedule 80 PVC socket fitting at a three-way junction — where a 12" primary main divides and distributes into a 12" straight-run continuation and a 12" perpendicular branch simultaneously, or where two 12" flows combine at a single fitting body. The hydraulic conditions at the equal tee junction on a 12" primary main are among the most demanding in the commercial PVC fitting line: the branch entry velocity, the directional change of flow from run to branch, and the pressure forces acting on the tee body at the three-way junction under full 12" primary main flow conditions all impose structural and pressure loading on the fitting that make Schedule 80 wall thickness and ASTM D2467 manufacturing compliance the correct and only specification at this service size and configuration. For commercial irrigation engineers, municipal water system civil engineers, industrial process piping mechanical engineers, and water treatment plant design engineers specifying 12" primary main branch connections where a full 12" port is required at the branch, the 801-120 is the catalog Schedule 80 PVC fitting that provides the manufactured, rated, specification-compliant single-body solution without field-fabricated tee assemblies, saddle connections, or custom fitting configurations that introduce additional joint count, potential leak points, and material class documentation complications at the primary main branch connection.

Schedule 80 gray PVC construction is the correct and only material specification for this fitting at the 12" equal tee configuration. The Schedule 80 wall thickness at the 12" port dimensions — applied uniformly across the run body, the branch body, and the full tee junction — provides the structural integrity, pressure performance, and mechanical robustness required at a 12" three-way primary main junction where internal pressure forces, hydraulic branch entry loads, and the mechanical weight and thermal movement of three connected 12" primary pipe runs impose the maximum combined structural loading of any fitting configuration in the commercial Schedule 80 PVC socket fitting line. The gray color provides permanent, inspectable Schedule 80 material class identification at the primary main tee junction — the most structurally and hydraulically active fitting location in the 12" system, and the location where material class confirmation carries the highest consequence for system commissioning documentation, AHJ inspection sign-off, and long-term infrastructure asset management. PVC Type 1 Grade 1 construction with cell classification 12454 per ASTM D1784 provides broad chemical resistance across water treatment chemicals, process water service, industrial utility water, and the full range of non-solvent process fluids appropriate for Schedule 80 PVC primary main service. All three socket ends solvent cement directly onto standard 12" IPS Schedule 40 or Schedule 80 PVC pipe using heavy-body solvent cement appropriate for the large bonding surface areas of each 12" socket. At the 12" socket connections, joint assembly is the most technically demanding in the commercial Schedule 80 PVC fitting line: heavy-body solvent cement rated for large-diameter Schedule 80 PVC is mandatory at all three connections, pre-planned assembly with all three pipe connections accessible and positioned before cement application begins is essential to manage working time across three large-diameter socket joints on a single fitting body, full circumferential heavy-body cement coverage across the complete bonding surface of each 12" pipe end and fitting socket must be achieved, and full cure time compliance before any system pressurization is non-negotiable at this primary main tee junction where partial cure under system pressure carries the most severe operational and infrastructure consequences of any equal tee configuration in the commercial PVC fitting line.

NSF 61 certification lists this fitting for potable water contact, and NSF 14 covers compliance with applicable plastics piping material standards — making it the correct primary main tee fitting for municipal water treatment and distribution systems, large potable water pump station distribution headers, and large commercial and institutional water supply primary mains where NSF-listed materials are required at every fitting in the primary distribution system. ASTM D2467 governs Schedule 80 PVC socket fittings and defines the manufacturing, dimensional, and pressure performance requirements the 801-120 is produced to. Verify manufacturer pressure rating documentation for the specific fitting configuration before final system specification — at the 12" equal tee configuration, the governing pressure rating is determined by the 12" port size and the fitting's tested performance at the equal tee geometry under the combined hydraulic conditions of three full-diameter 12" port connections, and must be confirmed against the manufacturer's published pressure-temperature rating table for SKU 801-120 before installation in systems at or near the fitting's rated pressure ceiling.

Key Features:

  • Schedule 80 gray PVC equal tee — 12" x 12" x 12", all socket (slip) ends
  • Equal configuration — full 12" branch port equal in diameter to the 12" primary run
  • Manufactured to ASTM D2467 — the governing standard for Schedule 80 PVC socket fittings
  • NSF 61 certified for potable water contact; NSF 14 listed
  • Solvent cement socket connections compatible with Schedule 40 and Schedule 80 IPS 12" pipe at all three ports
  • Gray color — universal Schedule 80 material class identification at the primary main tee junction
  • Single-body fitting for 12" equal branch takeoffs, equal flow splits, and three-way primary main distribution connections
  • Cell classification PVC 12454 per ASTM D1784
  • Heavy-body solvent cement required at all three 12" socket connections; full cure time compliance mandatory before pressurization
  • Pressure rating: verify against manufacturer pressure-temperature table for SKU 801-120

Specifications:

Attribute Value
SKU 801-120
Fitting Type Equal Tee
Run Size 12" x 12"
Branch Size 12"
End Connections Slip x Slip x Slip (All Socket)
Connection Method Solvent Cement (IPS)
Compatible Pipe — All Ports 12" IPS Schedule 40 or Schedule 80 PVC
Schedule Schedule 80
Material PVC (Polyvinyl Chloride) Type 1, Grade 1
Cell Classification 12454 per ASTM D1784
Color Gray
Manufacturing Standard ASTM D2467
Potable Water Certification NSF/ANSI 61
Plastics Standard Certification NSF 14
Max Service Temperature 140°F (60°C)
Pressure Rating Verify with manufacturer pressure-temperature rating table for SKU 801-120

Industries & Applications:

  • Municipal Water Distribution — Primary Transmission Main Equal Branch Connections — The 12" equal tee is specified at full 12" branch takeoff points on 12" municipal water transmission and primary distribution mains — connections supplying 12" zone transmission laterals, parallel distribution trunk branches, primary pressure zone supply headers, and large-diameter fire flow supply branches where the branch flow requirement at the 12" primary main junction demands a full 12" port that a reducing tee cannot provide without branch flow restriction; at municipal scale, the 12" primary transmission main is capital water supply infrastructure designed by licensed civil engineers and inspected by water system AHJs, and every branch connection fitting is a formally specified, permitted, and inspected infrastructure component — the 801-120 provides the manufactured, rated, NSF-listed, ASTM D2467-compliant single-body Schedule 80 PVC solution for the full 12" branch connection requirement at primary transmission main junction points in large municipal PVC water distribution system construction
  • Water Treatment Plant — Primary Header Equal Branch Connections — Installed at full 12" branch connection points on 12" primary distribution headers in municipal and industrial water treatment plants — clearwell supply and distribution primary trunks, filter influent and effluent primary headers, backwash primary supply mains, and plant service water primary headers where a full 12" branch connection serves a parallel filter train, a redundant supply path, a parallel treatment equipment supply, or an equal-capacity zone distribution branch; the equal tee configuration is specified where the branch flow requirement at the 12" primary header equals the primary run capacity and a reducing tee with a smaller branch port would create unacceptable flow restriction or velocity imbalance across the tee junction; NSF 61 listing makes this fitting appropriate for every potable water treatment primary distribution equal branch connection, and Schedule 80 gray PVC construction satisfies the material class requirements of water treatment plant primary distribution piping specifications at the largest service sizes
  • Pump Station — Primary Header Three-Way Connections and Flow Splits — Used at three-way connection points in large pump station primary headers where a 12" primary pump discharge or suction header must split equally into two parallel 12" distribution branches, where two 12" pump discharge connections must combine at a three-way primary header junction, or where a 12" primary suction or discharge header must supply a full 12" branch to a parallel pump train, zone isolation valve assembly, or primary check valve bypass connection; the equal tee geometry at 12" provides the full-diameter three-way junction capability for pump station header configurations where the branch flow volume, the primary suction or discharge hydraulic conditions, or the equal-distribution manifold design requires a full 12" branch port throughout the three-way connection; at primary pump station header connections of this scale, the 801-120 is the single-body manufactured Schedule 80 PVC solution that eliminates field-fabricated three-way assemblies and provides a rated, code-compliant primary manifold fitting
  • Industrial Process Piping — Primary Header Equal Branch Takeoffs — Used at full 12" branch connection points on 12" process water primary headers, cooling water primary distribution trunks, plant utility water primary mains, and large-volume industrial process fluid primary distribution headers in manufacturing plants, chemical processing facilities, petrochemical support facilities, and heavy industrial environments where the 12" primary process header must supply a full 12" branch to a major equipment train, a parallel process unit, a secondary distribution trunk, or an equal-capacity redundant supply path; Schedule 80 gray PVC construction provides the chemical resistance, structural wall thickness, and material class identification required at large-diameter primary header equal branch connections in industrial process piping systems where Schedule 80 is the system-wide material standard and every primary manifold fitting must carry full engineering specification documentation
  • Large Commercial & Agricultural Irrigation — Primary Trunk Equal Branch Connections — Specified at full 12" branch takeoff points on 12" primary irrigation transmission mains at the largest commercial irrigation systems — major golf course and resort irrigation systems, large-acreage corporate agricultural operations, municipal parks and sports complex irrigation systems, and regional landscape irrigation projects where a 12" primary transmission main must supply a full 12" zone transmission branch, a parallel sector supply header, or a secondary distribution trunk of equal capacity to the primary run; the equal tee configuration is the correct specification where the branch zone or sector flow requirement at the 12" primary main equals the primary run capacity and the hydraulic design requires a full 12" branch port to maintain the zone supply pressure and flow rate that the irrigation system design specifies; the 801-120 provides the manufactured, rated Schedule 80 PVC single-body solution for this primary transmission main equal branch configuration
  • Industrial Water & Wastewater Treatment — Primary Process Header Three-Way Junctions — Installed at equal three-way connection points on 12" primary process distribution headers in industrial wastewater treatment, water reclamation, and large-scale industrial water management facilities — clarifier influent primary headers splitting into parallel treatment trains, primary effluent distribution mains branching to parallel disposal or reuse systems, and primary sludge handling distribution headers serving parallel dewatering equipment trains where a full 12" three-way junction is required to maintain equal flow distribution across both branches of the primary process header; Schedule 80 gray PVC construction handles the chemical service, process fluid contact, and structural loading conditions at 12" primary process header equal three-way junctions in industrial treatment environments, and the single-body 801-120 configuration eliminates the fabricated fitting assemblies that add joint count and inspection complications at the primary process header level
  • HVAC & Large Commercial Mechanical Systems — Primary Main Three-Way Distribution — Specified at full 12" three-way junction points on 12" primary chilled water distribution mains, condenser water primary trunks, and large-capacity hydronic heating and cooling primary distribution headers in large commercial campus, institutional, and industrial mechanical systems where the 12" primary distribution main must split into a 12" straight-run continuation and a full 12" branch connection to supply parallel building loops, equal-capacity mechanical room supply headers, or redundant distribution paths of equal pipe diameter to the primary main; at the 12" primary distribution level in large commercial HVAC systems, three-way junction fittings are primary infrastructure components formally specified by licensed mechanical engineers, and the 801-120 provides the manufactured, rated, Schedule 80 gray PVC single-body solution for the 12" equal three-way distribution requirement in large commercial and institutional HVAC primary distribution systems where Schedule 80 PVC is the system material standard
  • Aquaculture, Large Recirculating Systems & Water Management Infrastructure — Used at full 12" three-way distribution and collection junction points in the largest commercial aquaculture facilities, regional hatchery systems, and large recirculating aquaculture systems (RAS) where primary water supply, recirculation, or distribution headers at the 12" size must branch equally at a three-way junction to supply parallel filtration trains, equal-capacity recirculation loops, or parallel water conditioning and treatment systems of equal flow capacity to the primary trunk; the 12" equal tee configuration is specified where the branch connection requirement equals the primary header diameter and a reducing tee would restrict the branch flow below the parallel system's design capacity; Schedule 80 PVC construction handles the continuous water contact and water treatment chemical exposure of primary aquaculture infrastructure, and NSF 61 listing confirms fitness for potable and process water contact at the primary distribution tee junction
Part #:
801-120
Product Family:
Sch 80 PVC
Carton Qty:
1
Pallet Qty:
6
Size:
12"