Reducing Tee, Slip x Slip x Slip 12" x 12" x 4" (C601-664)

SKU:
C601-664
|
UPC:
25528776091
Availability:
Typically ships within 24 hrs
$137.99

The 12" x 12" x 4" PVC Reducing Tee (C601-664) is a Class 125, slip-socket fitting that delivers a 4" branch outlet directly off a 12" pipeline run in a single, permanently bonded component — eliminating the need to assemble a full-size 12" tee with a separate downstream 12"x4" reducer to achieve the same branch configuration. With slip connections on all three ports, the C601-664 accepts solvent-welded pipe at both run ports and the branch outlet for a permanent, full-pressure assembly that maintains structural integrity and rated performance across the entire fitting body at the run-to-branch transition zone.

The three-size reduction from the 12" run to the 4" branch defines the specific hydraulic role this fitting plays in a large-diameter pipeline system. Unlike near-full-bore reducing tee configurations where the branch carries a dominant share of the mainline flow, the 12" to 4" step-down positions the C601-664 primarily as a primary service tap — a branch outlet large enough to supply a meaningful secondary flow volume to a zone valve station, pump bypass connection, chemical injection header, service lateral feed, or instrumentation manifold, while the 12" main continues to carry the bulk of the system flow with minimal disruption at the branch junction. This functional role makes the C601-664 one of the most broadly applicable configurations in the large-diameter C601 series, appearing across municipal water distribution, large-scale irrigation, industrial process piping, and fire protection systems wherever a 4" branch takeoff is the standard connection size for secondary feeds off a 12" transmission or distribution main.

The single-component approach integrates the branch size reduction directly into the fitting body, producing a cleaner hydraulic geometry at the branch junction and a more compact installation footprint than a two-fitting assembly. For system designers and contractors, the C601-664 also simplifies hydraulic modeling and as-built documentation at this junction — a single fitting with known K-factor characteristics versus a tee-plus-reducer assembly with combined head loss values that must be accounted for separately.

Manufactured from virgin PVC compound meeting ASTM D2466 dimensional standards, the C601-664 delivers the corrosion resistance, chemical inertness, and long-term durability that make PVC the preferred material for large-bore water distribution, irrigation infrastructure, and industrial fluid handling at this diameter and pressure class.


Specifications:

Specification Details
Part Number C601-664
Material PVC (Polyvinyl Chloride)
Pressure Rating Class 125 (125 PSI @ 73°F)
Connection Type Slip (Socket) x Slip (Socket) x Slip (Socket)
Run Size 12" x 12"
Branch Size 4"
Fitting Standard ASTM D2466
Joining Method Solvent Cement (IPS Weld) — all three ports
Temperature Rating Up to 140°F (60°C)
Color White/Off-White
NSF Listed NSF/ANSI 61 (potable water)

Heavy-bodied solvent cement is required for all socket joints at 4" and above; the 12" run sockets in particular require heavy-bodied cement and substantially extended cure schedules relative to small-bore practice. Allow the full cure time for the largest socket — the 12" run sockets — to govern the assembly hold period before pressurizing or backfilling. Thrust restraint or thrust blocking must be evaluated at all branch tee locations in pressurized buried systems at 12" diameter; unbalanced thrust forces at this size under Class 125 pressure are substantial and require engineered restraint solutions in most buried service applications. Pressure-temperature derating applies at elevated service temperatures per ASTM standards.


Industries & Applications:

  • Municipal Water Distribution — 12" transmission and primary distribution mains requiring a 4" branch feed to service zone lateral connections, fire hydrant supply lines, pressure monitoring stations, booster station inlet taps, blow-off assemblies, or air release valve connections where the 4" branch size is standard for municipal service-level secondary feeds off a large transmission main
  • Agricultural & Large-Scale Irrigation — 12" mainline trunk distribution with a 4" branch drop to zone valve stations, pump bypass connections, filter manifold inlets, fertigation injection headers, or sub-main distribution feeds on large farms, golf courses, and managed landscape campuses where 4" is the standard branch size for zone-level secondary distribution off a 12" system trunk
  • Industrial Process Piping — High-volume fluid transfer headers requiring a 4" branch takeoff to a secondary process loop, equipment inlet connection, chemical dosing header, bypass circuit feed, or secondary distribution line where a 4" branch carries a defined secondary flow volume off a 12" primary supply main without a multi-fitting branch assembly
  • Water & Wastewater Treatment — Plant distribution mains supplying 4" branch feeds to chemical dosing skid connections, filtration system inlet taps, aeration distribution sub-headers, UV system supply lines, or instrumentation manifold feeds where Class 125 pressure rating meets the service conditions and the 4" branch serves a defined secondary process function
  • Fire Protection Supply Systems — Underground or above-grade 12" fire suppression supply mains with a 4" branch feed to hydrant laterals, sprinkler system risers, standpipe supply connections, or dedicated suppression loop feeds where 4" is the standard branch size for fire protection service connections off a large-diameter supply main
  • Stormwater & Flood Control Infrastructure — Large-diameter gravity or low-pressure stormwater collection and conveyance systems requiring a 4" lateral branch connection off a 12" trunk main at catch basin inlets, roof drain laterals, perimeter drainage connections, or below-grade routing junction points
  • Power Generation & Industrial Cooling — Cooling water distribution mains requiring a 4" branch connection to chemical treatment injection skids, side-stream filtration units, individual equipment cooling circuits, or secondary cooling loop feeds where the 4" branch size matches the secondary flow requirement at the equipment connection point
  • Aquaculture & Water Management — High-flow recirculation, intake, or discharge headers requiring a 4" branch takeoff to individual raceway inlet manifolds, aeration system feeds, treatment system supply connections, or secondary distribution circuits where 4" branch capacity matches the zone-level flow requirements of the facility layout
(No reviews yet)
Width:
20.44 (in)
Height:
13.63 (in)
Depth:
27.25 (in)
Condition:
New
Current Stock:
Adding to cart… The item has been added

The 12" x 12" x 4" PVC Reducing Tee (C601-664) is a Class 125, slip-socket fitting that delivers a 4" branch outlet directly off a 12" pipeline run in a single, permanently bonded component — eliminating the need to assemble a full-size 12" tee with a separate downstream 12"x4" reducer to achieve the same branch configuration. With slip connections on all three ports, the C601-664 accepts solvent-welded pipe at both run ports and the branch outlet for a permanent, full-pressure assembly that maintains structural integrity and rated performance across the entire fitting body at the run-to-branch transition zone.

The three-size reduction from the 12" run to the 4" branch defines the specific hydraulic role this fitting plays in a large-diameter pipeline system. Unlike near-full-bore reducing tee configurations where the branch carries a dominant share of the mainline flow, the 12" to 4" step-down positions the C601-664 primarily as a primary service tap — a branch outlet large enough to supply a meaningful secondary flow volume to a zone valve station, pump bypass connection, chemical injection header, service lateral feed, or instrumentation manifold, while the 12" main continues to carry the bulk of the system flow with minimal disruption at the branch junction. This functional role makes the C601-664 one of the most broadly applicable configurations in the large-diameter C601 series, appearing across municipal water distribution, large-scale irrigation, industrial process piping, and fire protection systems wherever a 4" branch takeoff is the standard connection size for secondary feeds off a 12" transmission or distribution main.

The single-component approach integrates the branch size reduction directly into the fitting body, producing a cleaner hydraulic geometry at the branch junction and a more compact installation footprint than a two-fitting assembly. For system designers and contractors, the C601-664 also simplifies hydraulic modeling and as-built documentation at this junction — a single fitting with known K-factor characteristics versus a tee-plus-reducer assembly with combined head loss values that must be accounted for separately.

Manufactured from virgin PVC compound meeting ASTM D2466 dimensional standards, the C601-664 delivers the corrosion resistance, chemical inertness, and long-term durability that make PVC the preferred material for large-bore water distribution, irrigation infrastructure, and industrial fluid handling at this diameter and pressure class.


Specifications:

Specification Details
Part Number C601-664
Material PVC (Polyvinyl Chloride)
Pressure Rating Class 125 (125 PSI @ 73°F)
Connection Type Slip (Socket) x Slip (Socket) x Slip (Socket)
Run Size 12" x 12"
Branch Size 4"
Fitting Standard ASTM D2466
Joining Method Solvent Cement (IPS Weld) — all three ports
Temperature Rating Up to 140°F (60°C)
Color White/Off-White
NSF Listed NSF/ANSI 61 (potable water)

Heavy-bodied solvent cement is required for all socket joints at 4" and above; the 12" run sockets in particular require heavy-bodied cement and substantially extended cure schedules relative to small-bore practice. Allow the full cure time for the largest socket — the 12" run sockets — to govern the assembly hold period before pressurizing or backfilling. Thrust restraint or thrust blocking must be evaluated at all branch tee locations in pressurized buried systems at 12" diameter; unbalanced thrust forces at this size under Class 125 pressure are substantial and require engineered restraint solutions in most buried service applications. Pressure-temperature derating applies at elevated service temperatures per ASTM standards.


Industries & Applications:

  • Municipal Water Distribution — 12" transmission and primary distribution mains requiring a 4" branch feed to service zone lateral connections, fire hydrant supply lines, pressure monitoring stations, booster station inlet taps, blow-off assemblies, or air release valve connections where the 4" branch size is standard for municipal service-level secondary feeds off a large transmission main
  • Agricultural & Large-Scale Irrigation — 12" mainline trunk distribution with a 4" branch drop to zone valve stations, pump bypass connections, filter manifold inlets, fertigation injection headers, or sub-main distribution feeds on large farms, golf courses, and managed landscape campuses where 4" is the standard branch size for zone-level secondary distribution off a 12" system trunk
  • Industrial Process Piping — High-volume fluid transfer headers requiring a 4" branch takeoff to a secondary process loop, equipment inlet connection, chemical dosing header, bypass circuit feed, or secondary distribution line where a 4" branch carries a defined secondary flow volume off a 12" primary supply main without a multi-fitting branch assembly
  • Water & Wastewater Treatment — Plant distribution mains supplying 4" branch feeds to chemical dosing skid connections, filtration system inlet taps, aeration distribution sub-headers, UV system supply lines, or instrumentation manifold feeds where Class 125 pressure rating meets the service conditions and the 4" branch serves a defined secondary process function
  • Fire Protection Supply Systems — Underground or above-grade 12" fire suppression supply mains with a 4" branch feed to hydrant laterals, sprinkler system risers, standpipe supply connections, or dedicated suppression loop feeds where 4" is the standard branch size for fire protection service connections off a large-diameter supply main
  • Stormwater & Flood Control Infrastructure — Large-diameter gravity or low-pressure stormwater collection and conveyance systems requiring a 4" lateral branch connection off a 12" trunk main at catch basin inlets, roof drain laterals, perimeter drainage connections, or below-grade routing junction points
  • Power Generation & Industrial Cooling — Cooling water distribution mains requiring a 4" branch connection to chemical treatment injection skids, side-stream filtration units, individual equipment cooling circuits, or secondary cooling loop feeds where the 4" branch size matches the secondary flow requirement at the equipment connection point
  • Aquaculture & Water Management — High-flow recirculation, intake, or discharge headers requiring a 4" branch takeoff to individual raceway inlet manifolds, aeration system feeds, treatment system supply connections, or secondary distribution circuits where 4" branch capacity matches the zone-level flow requirements of the facility layout
Part #:
C601-664
Product Family:
Class 125 PVC
Carton Qty:
1
Pallet Qty:
6
Size:
12"